Series 613
INSTALLATION
984360EC
Edition 12.08.2022
53/149
Compressed Air
Pressure
10A40000
FLOAT
RW
NV
mbar*
Only for series 65.3
Compressed Air Error
Enable
10A90000
BOOL
RW
NV
Only for series 65.3
Speed Mode
10990000
0: Low Speed
1: Mid Speed
2: High Speed
3: Undefined
4: IC Slow Pos/Slow Prs
5: IC Fast Pos/Slow Prs
6: IC Fast Pos/Fast Prs
Available speed Mode depends
on valve series
5.12.7.3
Position Control
Sub Group
Parameter
ID [hex]
Data Type Acc
NV
Unit
Min
Max
Description
Actual Position
11010000
FLOAT
RO
V
[pos]*
0
100
Target Positon
11020000
FLOAT
RW
V
[pos]*
0
100
Position Control
Speed
11030000
FLOAT
RW
NV
0.001
1
Speed valid in Control Mode = Position
1.0 equals to full speed
Ramp
Enable
11620100
BOOL
RW
NV
0
1
Activate/Deactivate position target ramp.
Time
11620200
FLOAT
RW
NV
sec
0
1000000
Slope
11620300
FLOAT
RW
NV
mbar*/sec
0
100000000
Mode
11620400
UINT8
RW
NV
0
1
0:Use Ramp Time
1:Use Ramp Slope
Type
11620500
UINT8
RW
NV
0
2
0:Linear
1:Logarithmic
2:Exponential