Series 613
INSTALLATION
984360EC
Edition 12.08.2022
61/149
System
Set
Resp
Get
Resp
Data
Set, Get Resp
Description
i:76
i:76
aaaaaa
bbbbbbbbcde
Compound
a Pressure
b Position
c Access Mode:
0=Local, 1=Remote, 2=Locked
d Control Mode:
0=Init,1=Homing,2=Position,3=Close,4=Open,5=Pressure
Control,6=Hold,7=Learn,8=Interlock Open,9=Interlock Close,12=Power
Failure,13=Safety,14=Error
e Warning Present:
(in i:51 or i:52)
0=no, 1=yes
s:04
s:04
i:04
i:04
abcdefgh
Valve Configuration
a Homing End Position:
0=Close, 1=Open
b Power Failure Position:
0=Close, 1=Open
c External Isolation Valve Enable:
0=no, 1=yes
d Control Stroke Limitation Enable:
0=no, 1=yes
e Network Failure Position
f Cluster Valve Offline
g Homing Start:
0=Not Isolated or Move Command, 1=c:4303 Command,
2=Open Command, 3=Move Command, 1=At Power Up
h Reserved
i:50
i:50
aaa
Fatal Error Number:
20=Limit Stop Not Detected, 21=Blocked, 22=Blocked, 40=Motor Driver
c:53
c:53
i:51
i:53
i:51
i:53
abcdefgh
Warnings 1
a Service Request
b Learn Data Warning
c PFO not ready
d Compressed Air Failure
e Sensor Ratio
f External Isolation Valve Warning
g Cluster Slave Offline
h Network Failure
i:53 = nonvolatile, c :5300 = reset
c:54
c:54
i:52
i:54
i:52
i:54
abcdefgh
Warnings 2
a Rom Memory
b Interface
c Sensor ADC
d Interface ADC
e Reserved
f Sensor value not valid
g Cluster Slave Offline
h Network Failure
i:54 = nonvolatile,
c :5400 = reset
c:20
c:20
i:70
i:70
aaaaaaaaaa
Counter Control Cycles
c:2000 = reset
c:21
c:21
i:71
i:71
aaaaaaaaaa
Counter Isolation Cycles
c:2100 = reset
c:22
c:22
i:72
i:72
aaaaaaaaaa
Counter Power Up
c:2200 = reset
c:10
c:10
aa
Power Failure Option Off:
0=Off (volatile), 1=On
c:82
c:82
aa
Reset:
1=Reset