Required tool
9. Remove the wire coat carefully about 5mm
Wire strippers
10. Insert the cable(s) at connector hosing as
shown in the pictures, see also chapter CC-
Link connector
Note:
If valve in CC-Link network is at «first or last
station» install the CC-Link cable at position
A and close B with blind plug C.
If valve in CC-Link network at
«…stations…» install the CC-Link cables at
position A and B.
11. Fasten the strain-relief screw until the cable
can not pulled out by manual force
Screw driver
size 4
5mm
Shield
Pos. A
Pos. B