Installation, Operating & Maintenance Instructions
Series 650 DN 350 (I.D. 14”), CC-Link
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 CH@vatvalve.com www.vatvalve.com
286241EA
2010-10-11
32/86
3.5 Display
information
There is a 4 digit display located on the panel.
It displays configuration, status and position
information. For details refer to following
tables.
Power up:
Description
Digit 1
Digit 2
Digit 3
Digit 4
1 E
0
0
At first all dots are illuminated
then configuration is displayed:
•
Firmware version [e.g. 1E00]
(1
st
information for about 2s)
•
Controller configuration
(2
nd
information for about 2s)
In case D C or D999 is displayed,
motor interlock is active. Refer to
«Safety mode» for details.
If valve is closed (isolated) display
shows alternately C C and INIT.
Synchronization will be done
when first movement command is
received.
A
= No or unknown
busmodule detected
I
= CC-Link
interface
0
= basic
1
= with SPS
1)
2
= with PFO
2)
3
= with SPS
1)
and PFO
2)
1
= 1 sensor version
2
= 2 sensor version
SYNC indicates that
synchronization is running.
S Y
N
C
1) SPS = optional ±15 VDC Sensor Power Supply module
2) PFO = optional Power Failure Option
Display
1 2 3 4