3.11.2 Location of the handshaking bits
Slave
Æ
Master
Master
Æ
Slave
Device
Signal name
Device No.
Signal name
RX m0
RY m0
RX m1
RY m1
RX m2
RY n2
RX m3
RY m3
RX m4
RY m4
RX m5
RY m5
RX m6
RY m6
RX m7
RY m7
RX m8
RY m8
RX m9
RY m9
RX mA
RY mA
RX mB
RY mB
RX mC
RY mC
RX mD
RY mD
RX mE
RY mE
RX mF
RY mF
to
Not used
to
Not used
RX(m+n)0
RY(m+n)0
RX(m+n)1
RY(m+n)1
RX(m+n)2
RY(m+n)2
RX(m+n)3
RY(m+n)3
RX(m+n)4
RY(m+n)4
RX(m+n)5
RY(m+n)5
RX(m+n)6
RY(m+n)6
RX(m+n)7
Reserved
RY(m+n)7
Reserved
RX(m+n)8
Initial data processing request flag
RY(m+n)8
Initial data processing complete flag
RX(m+n)9
Initial data setting complete flag
RY(m+n)9
Initial data setting request flag
RX(m+n)A
Error status flag
RY(m+n)A
Error reset request flag
RX(m+n)B
Remote READY
RY(m+n)B
RX(m+n)C
RY(m+n)C
RX(m+n)D
RY(m+n)D
RX(m+n)E
RY(m+n)E
RX(m+n)F
Reserved
RY(m+n)F
Reserved
Table 1: Bit Memory Map Profile of VAT CC-Link slave
m : Address assigned to the master module by the station number setting. This means that the address range for this
slave begins at address m of the master.
n : Dependent on the VAT Operational settings mode (number of occupied stations and number of extension cycles)
Operational settings mode = 1
Æ
n = 0x7 (hex)
Operational settings mode = 4
Æ
n = 0xD (hex)
Example see chapter: 3.11.3 Example of the handshaking by a PLC-program.