10
Any temperature adjustments of thermostats must be made by qualified service
personnel as follows:
1.
Shut off or disconnect all electrical service to the heater.
2.
Remove the cover panel with an insulated handle screwdriver.
a.
Adjust the pointer on both thermostats with the insulated screwdriver to the
desired temperature and check to see that the proper temperature is achieved.
(Do not remove protective cover from thermostat.)*
3.
Replace the cover panel and reconnect electrical service.
4.
Be sure that insulation is replaced carefully. Malfunction of the thermostat
will occur if voids are left in the insulation.
*Both upper and lower thermostats should be set at the same temperature under
normal residential conditions.
SAFETY CONTROLS
The heater has a combination thermostat and hi-limit control that is located
above the top-heating element.
This surface mounted hi-limit is designed to interrupt the flow of
electricity to all elements when it senses temperatures of approximately
170°F or greater. If this switch operates, do not attempt to reset. A
dangerous situation is indicated and a qualified service man should be called
to find the source before the unit is operated again
.
Temperature of the water should be tested periodically at the faucet to be sure
thermostats are working properly.