background image

12 Vaultek

®

Biometric Scanner:

 Delete Fingerprints

Individual fingerprints can not be deleted from the keypad on the safe. Following this procedure will erase all of 

the fingerprints including both administrative fingerprints. If you wish to delete individual fingerprints, refer to 

the Vaultek

®

 app. This procedure will not affect the keypad master code.

Press and hold keys '1' and "PROGRAM" button together until 

all

 the keys light up RED and let go.

Enter your master code on the keypad. If the code is correct, all the keys will blink GREEN and safe will beep 

indicating deletion of 

all

 the fingerprints.

For setup, tutorials, and FAQs visit 

www.vaulteksafe.com/support/slider-series/

11 Vaultek

®

Biometric Scanner: 

Programming Additional Prints 3 to 20

After the first two Admin fingerprints have been locked in, you can add additional users or fingerprints, up to 

20 unique users in total. This is very helpful in the event the fingerprint scanner is having a hard time reading 

your initial fingerprints, or if you wish to grant other users authorized access to your safe. Any additional users 

programmed require authorization from one of the two Admin fingerprints.

Open the safe. Program additional fingerprints by quickly pressing and releasing the "PROGRAM" button (3 

seconds) (Figure L on page 10). When all keys (1-5) are blinking RED scan one of the administrative fingerprints.

Place one of the first two programmed administrative fingerprints on the scanner and remove when the safe 

beeps and the fingerprint LED blinks GREEN. When the '1' key starts blinking RED you can enroll a NEW fingerprint.

Troubleshooting!

 If the administrative print is left on the scanner too long the safe will begin to program that 

fingerprint into the safe again and not the NEW fingerprint. If this happens start over with step one.

Using the helpful programming tips provided on page 09 place the NEW finger on the scanner. When the safe 

beeps and the '1' key lights up GREEN remove your finger.

Place finger again over the scanner at a slightly different angle until the safe beeps and the '2' key lights up 

GREEN and lift. You will repeat this process until all keys (1-5) are solid GREEN.

Tip!

 Repeat steps 1 through 4 to add additional fingerprints.

Troubleshooting!

 If you are having difficulty with your print, program the same fingerprint 4 or 5 times. You have 

20 slots available for programming and you can also try your thumb as it has more surface area to read.

Continue on next page to learn how to delete fingerprints.

For setup, tutorials, and FAQs visit 

www.vaulteksafe.com/support/slider-series/

Summary of Contents for SLIDER SR20

Page 1: ...Quick Setup Scan code use phone camera or visit www vaulteksafe com support slider series S R 2 0 i S R 2 0 I N S T R U C T I O N M A N U A L ...

Page 2: ...Alert of Manual Unlock Factory Reset Dual Entry Mode Vaultek Bluetooth 2 0 App Overview Pairing Securing Your Safe Multiple Plate Configurations Mounting Bracket Installation Removing Safe from Mounting Plate Troubleshooting FAQ Customer Support Warranty 15 15 16 16 16 16 16 16 17 18 17 18 19 21 19 20 21 22 23 24 Thank You At Vaultek we stand behind our product and you our customer On behalf of th...

Page 3: ... that lights up when your hand brushes against the safe See page 07 for more information Nano Key Optional Accessory Remote for on demand access See page for 13 and 14 for more information Vaultek Bluetooh App Manage the safe with the Bluetooth app See pages 17 and 18 for more information Manual Key Two keys are provided for manual access to the safe in the event the battery dies Secure Defense Ho...

Page 4: ...emarks owned by the Bluetooth SIG Inc and any use of such marks by Vaultek Safe Inc is under license Battery Installation Your safe uses a 3 7V 18650 rechargeable lithium ion with a flat top A minimum 2000 mAh capacity is required however 2200 mAh or higher can be used to increase operation time Battery Operation Battery Installation To get started open the safe using one of your backup keys via t...

Page 5: ...ove when using micro USB cable See the FAQ section for additional information about the battery D 06 Vaultek Battery Maintenance Battery Maintenance Testing the Battery Power To check the battery level press and hold the 5 key on the keypad for 3 seconds The keys will glow GREEN or RED to indicate the battery level Remaining Battery Capacity Level If 4 keys glow green 80 100 If 3 keys glow green 6...

Page 6: ... to guess your code For your security the safe will time out and sleep for 4 minutes if 6 incorrect entries are made Two keys cannot be pressed simultaneously Programming a new code will overwrite your previous code E 08 Vaultek Product Registration Vaultek strongly encourages you to register your safe as soon as you receive it Registration provides many benefits including three year warranty tech...

Page 7: ...fication and authentication purposes The smart align biometric system guides your finger placement for consistent and accurate results Everyone has their own unique fingerprints and what makes them unique is the pattern of ridges valleys and minutiae points that comprise an individual print Vaultek and their leading engineering group has developed proprietary technology to read and match fingerpri...

Page 8: ...ditional fingerprints by quickly pressing and releasing the PROGRAM button 3 seconds Figure L on page 10 When all keys 1 5 are blinking RED scan one of the administrative fingerprints Place one of the first two programmed administrative fingerprints on the scanner and remove when the safe beeps and the fingerprint LED blinks GREEN When the 1 key starts blinking RED you can enroll a NEW fingerprint...

Page 9: ... Immediately aim Nano Key 2 0 towards the safe Press and hold the Nano Key 2 0 button until the safe keypad flashes GREEN to indicate pairing is successful Troubleshooting If the keypad does not flash green after step 2 then simply start over with step 1 Nano Key 2 0 Unpairing In the event a Nano Key Bluetooth 2 0 is lost or stolen you can unpair the lost Nano Key 2 0 from the safe s memory This w...

Page 10: ...tting press and hold keys 1 and 3 together for 3 seconds If the 2 4 and 5 keys glow GREEN the sound is High if the 2 and 4 keys glow GREEN the sound is Medium if the 2 key glows GREEN the sound is Low and if the 2 key glows RED the sound is OFF The sound is Medium pitch by default 15 Vaultek Travel Mode Save battery life by disabling the proximity sensor fingerprint sensor keypad and Bluetooth fea...

Page 11: ...s and control over features that are not possible using the keypad interface alone To get started download and install the Vaultek app for free from the Google Play store or Apple store and pair your phone with your safe Vaultek Bluetooth 2 0 App App Features Unlock Safe Within Range Optional Check Battery Levels Toggle Sound On Off Adjust Interior Light Manage Fingerprint IDs Biometric Model Only...

Page 12: ...ion Securing Your Safe Mounting Safe Locate the 4 receiving slots located on the safe sides and the 4 tabs located on the mounting plate Fully insert the tabs on the mounting plate into the receiving slots on the safe Figure N O and press the safe downwards to lock in place Figure P Tip Your safe can install on the mounting plate from the left or right side When installing the plate be sure the bo...

Page 13: ...button together for 3 seconds Repeat the sequence to disable the unlock feature Fingerprint scanner works sometimes and not others Biometric Model Only The most helpful tip is to program the same finger 4 or 5 times You have 20 slots available for programming and you can also try your thumb as it has more surface area to read More tips on page 09 The keypad is flashing If Alert of Manual Unlock is...

Page 14: ...RER SHALL BE LIABLE FOR ANY INJURY LOSS OR DAMAGE DIRECT OR CONSEQUENTIAL ARISING OUT OF THE USE OF OR THE INABILITY TO USE THE VAULTEK SAFE FAQ More online at vaulteksafe com and select Support Can I keep the safe plugged in at all times Leaving your safe plugged in continually will not harm the safe or battery However to preserve the battery life we suggest that you unplug occasionally to allow ...

Page 15: ... FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular in...

Page 16: ...REV 032122 37 North Orange Ave Suite 770 Orlando FL 32801 ...