background image

OPERATING MANUAL 2000 GS                                                                                  V7.4/20-EN 

Page| 4 

The following applies to all maintenance and repair work:

 

 

It is essential to disconnect the spray gun from the compressed 
air connection. 

 

Only use original spare parts. 

 

The  maximum  working  pressure  must  not  be  exceeded  (see 
point 1 "Technical data"). The working pressure must be ad-
justed via a (filter) pressure reducer. 

 

Only use compressed air as energy source. 

 

The compressed air connection may only be made via a quick 
coupling. 

 

When working with the spray gun, wear the necessary protec-
tive clothing, protective goggles, work gloves, ear protection if 
necessary and a respirator mask. 

 

If there are leaks in the device or other operating faults, the 
device must be disconnected from the compressed air supply 
immediately and the cause of the fault must be eliminated. 

 

Open fire, sparks or smoking is prohibited. 

 

Beware of flammable materials. 

 

Stone chip and underbody protection remains as well as 
cleaning  media  must  be  disposed  of  in  an  environmentally 
friendly manner. 

 

The disposal of the compressed air device must be carried out 
according to the valid legal regulations. 

 

6.

 

Installation 

Screw in the supplied steel riser pipe hand-tight. Pierce the protective foil of 
the 1 litre can and dip the riser pipe into the spraying material. Screw the 1 litre 
can into the plastic threaded cap of the spray gun 

hand-tight

. Take care not to 

overtighten the thread! 
Connect the spray gun to the compressed air supply via the quick coupling. By 
pressing the trigger you put the spray gun into operation. 
The spray pattern can be influenced by the following factors:

 

 

Distance between spray nozzle and object 

 

Angle of the gun to the object 

 

Optionally with this spray gun you have the possibility to preserve cavities. For 
this  purpose  the  brass  spray  pipe  (2900  GS)  must  be  separated  from  the 
threaded connection piece (H26) and replaced by an optionally available cavity 
spray hose (2900 H).

 

 
 
 
 
 

Summary of Contents for 2000 GS

Page 1: ...OPERATING MANUAL 2000 GS V7 4 20 EN Page 1 Spray gun 2000 GS Art no 20301 20313 ...

Page 2: ...ays keep this operating manual with the spray gun General notices This spray gun was developed for certain applications We explicitly point out that this spray gun must not be modified and or used in a way that does not corre spond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation 4 7 Maintenance and care 5 8 ...

Page 3: ... by taking appropriate precautions against the risk of accidents and observe the following instructions in your own interest The operator must ensure proper operation Do not bring compressed air stone chip or underbody protec tion into contact with skin or eyes Keep children and pets away from the operating area Never direct the spray jet at animals people or yourself No manipulations emergency re...

Page 4: ...of flammable materials Stone chip and underbody protection remains as well as cleaning media must be disposed of in an environmentally friendly manner The disposal of the compressed air device must be carried out according to the valid legal regulations 6 Installation Screw in the supplied steel riser pipe hand tight Pierce the protective foil of the 1 litre can and dip the riser pipe into the spr...

Page 5: ...check whether there is sufficient com pressed air available whether the spray material can still be processed wheth er the expiry date has passed or whether the material has dried out Gun sprays messy Possible cause Spray pipe riser pipe and or ventilation hole dirty Solution Clean parts Gun does not spray any material Possible cause Riser pipe and or spray pipe clogged Solution Clean clogged part...

Page 6: ...n must be in its original condition 11 Address In case of service your sales representative is at your side or contact the following address Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ from t...

Page 7: ...ty with the above EC Directives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating manual belonging to the...

Page 8: ... 60 3103 003 Spring for valve 9 60 4100 062 O ring 8 x 1 mm 10 30 1120 002 Locking screw 11 30 1424 009 Air nozzle 2 0 mm 13 10 1431 001 Connection piece H26 14 60 4100 011 O ring 8 x 2 mm 15 29002 Cavity spray hose 2900 H 16 30 1124 001 Brass spray pipe 2900 GS 21 40 4112 010 Threaded cap standard black 40 4112 012 Threaded cap USA red 21 A Ventilation hole 22 30 1432 018 Fixing screw m 10 x 1 mm...

Reviews: