background image

OPERATING MANUAL 2000 MS                                                                                 V7.4/20-EN 

Page| 4 

 

It is essential to disconnect the spray gun from the compressed 
air connection. 

 

Only use original spare parts. 

 

 

The maximum working pressure must not be exceeded (see 

point 1 "Technical data"). The working pressure must be ad-
justed via a (filter) pressure reducer. 

 

Only use compressed air as energy source. 

 

The compressed air connection may only be made via a quick 
coupling. 

 

When working with the pressure cup gun, wear the necessary 
protective clothing, protective goggles, work gloves, ear pro-
tection if necessary and a respirator mask. 

 

If there are leaks in the device or other operating faults, the 
device must be disconnected from the compressed air supply 
immediately and the cause of the fault must be eliminated. 

 

Open fire, sparks or smoking is prohibited. 

 

Beware of flammable materials. 

 

Stone chip and underbody protection remains as well as clean-
ing media must be disposed of in an environmentally friendly 
manner. 

 

The disposal of the compressed air device must be carried out 
according to the valid legal regulations. 

 

6.

 

Installation 

Screw in the supplied steel riser pipe hand-tight. Pierce the protective foil of 
the 1 litre can and dip the riser pipe into the spraying material. Screw the 1 litre 
can into the plastic threaded cap of the spray gun 

hand-tight

. Take care not to 

overtighten the thread! 
Connect the spray gun to the compressed air supply via the quick coupling. By 
pressing the trigger you put the spray gun into operation. 
The spray pattern can be influenced by the following factors:

 

 

Distance between spray nozzle and object 

 

Angle of the gun to the object 

 

By adjusting the brass spray pipe 
 

7.

 

Maintenance and care 

After each use, disconnect the device from the compressed air supply and thor-
oughly  clean  it.  We  recommend  benzine  or  commercially  available  terpene-
based cleaners. 

Do not use aggressive cleaners! 

Following the maintenance in-

structions will ensure a long service life and trouble-free operation of this qual-
ity product. 
 
 
 

Summary of Contents for 2000 MS

Page 1: ...OPERATING MANUAL 2000 MS V7 4 20 EN Page 1 Spray gun 2000 MS Art no 20101 20110...

Page 2: ...ys keep this operating manual with the spray gun General notices This spray gun was developed for certain applications We explicitly point out that this spray gun must not be modified and or used in a...

Page 3: ...air stream is used which accelerates when the air nozzle flows through and thus generates negative pressure in the adjoining riser pipe The spray mass is thereby sucked in and sprayed out via the noz...

Page 4: ...ia must be disposed of in an environmentally friendly manner The disposal of the compressed air device must be carried out according to the valid legal regulations 6 Installation Screw in the supplied...

Page 5: ...ole dirty Solution Clean parts Gun does not spray any material Possible cause Riser pipe brass spray pipe clogged Solution Clean clogged parts Air escapes from the spray nozzle even though the trigger...

Page 6: ...ative is at your side or contact the fol lowing address Vaupel GmbH Ger tebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh d...

Page 7: ...ce with the above EC guidelines under the general responsibility of Company Vaupel GmbH Ger tebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete T...

Page 8: ...5 80158 Valve bolt 6 O ring 1 5 x 0 75 mm 7 Valve seal 8 60 3103 003 Spring for valve 9 60 4100 062 O ring 8 x 1 mm 10 30 1120 002 Locking screw 12 30 1422 008 Air nozzle 2 5 mm 18 30 3410 004 Lock n...