Protect yourself and the environment by taking appropriate precautions against 
the risk of accidents and observe the following instructions in your own inter-
est: 
 

 

The operator must ensure proper operation. 

 

 

Do not bring compressed air and/or medium into contact with 

skin or eyes. 

 

Never direct the spray jet at animals, people or yourself.  

 

Keep children and pets away from the operating area. 

 

No  manipulations,  emergency  repairs  or  misappropriations 
may be carried out on the pressure cup gun. 

 

Pressure cup guns may only be operated and maintained  by 
instructed persons.  

 

Repairs must only be carried out by qualified persons. 
 

The following applies to all maintenance and repair work:  

 

It  is  essential  to  disconnect  the  pressure  cup  gun  from  the 
compressed air connection before carrying out maintenance 
or repair work. 

 

Only use original spare parts. 

 

The  maximum  working  pressure  must  not  be  exceeded  (see 
point  1  "Technical  data").  The  working  pressure  must  be 
adjusted via a (filter) pressure reducer. 

 

Only use compressed air as energy source. 

 

The compressed air connection may only be made via a quick 
coupling. 

 

When working with the pressure cup gun, wear the necessary 
protective clothing, protective goggles, work gloves, ear pro-
tection if necessary and a respirator mask. 

 

If there are leaks in the device or other operating faults, the 
device must be disconnected from the compressed air supply 
immediately and the cause of the fault must be eliminated. 

 

Open fire, sparks or smoking is prohibited. 

 

Beware of flammable materials. 

 

Processed media and cleaning media must be disposed of in 
an environmentally friendly manner. 

 

The disposal of the compressed air device must be carried out 
according to the valid legal regulations. 

 
 
 

 
 
 

Summary of Contents for 3000 DV

Page 1: ...OPERATING MANUAL 3000 DV DVR V5 4 20 EN Page 1 Pressure cup spray gun 3000 DV DVR Art no 30001 30411 30112 30401 Illustration shows 3000 FGR ...

Page 2: ... keep this operating manual with the pressure cup gun General notice This pressure cup gun was developed for certain applications We explicitly point out that this pressure cup gun must not be modified and or used in a way that does not correspond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation end of work 5...

Page 3: ...Extent of delivery Pressure cup gun compressed air connection operating manual Additionally included with 3000 DVR Set Hose set 3900 WH 02 or 04 3 Intended use This pressure cup gun is a compressed air operated quality tool for professional use It is suitable for processing liquid media in the form of commercially avail able 1 litre cans 4 Features The effectiveness of the pressure cup gun 3000 DV...

Page 4: ...rom the compressed air connection before carrying out maintenance or repair work Only use original spare parts The maximum working pressure must not be exceeded see point 1 Technical data The working pressure must be adjusted via a filter pressure reducer Only use compressed air as energy source The compressed air connection may only be made via a quick coupling When working with the pressure cup ...

Page 5: ...ced by the following factors Material quantity via stop screw nozzle needle Adjusting the intake pressure Spraying air via knurled screw on gun head For fine jet add a lot of air For coarse jet add little air Distance between spray nozzle and object Angle of the gun to the object End of work Vent the pressure container using the exhaust valve pos 24 only for 3000 DVR Disconnect the device from the...

Page 6: ...n sprays messy Possible cause Adjustment options not optimally adjusted Solution Operating pressure spraying air material quantity to be adjusted to each other Gun does not spray any material Possible cause The riser pipe and or spray nozzle are clogged Solution Clean clogged parts Air escapes from the spray nozzle even though the trigger is in its initial position Possible cause Valve bolt is jam...

Page 7: ...efects Excluded from the warranty Wear parts Damage caused by improper use Damage caused by lack of maintenance Damage caused by dirt Damage caused by untreated compressed air If warranty claims are made the pressure cup gun must be in its original condi tion 11 Address In case of service your sales representative is at your side or contact the follow ing address Vaupel GmbH Gerätebau Drucklufttec...

Page 8: ...ccordance with the above EC Directives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating instructions bel...

Page 9: ...pray nozzle 3000 19 60 4100 314 O ring 10 x 2 mm 20 30 1411 007 Air nozzle SW 17 mm 21 83313 O ring 15 x 2 mm 22 Adapter 3000 23 O Ring 33 x 2 mm 24 80502 Exhaust air valve only with 3000 DVR 25 10 2112 006 Container lid with 26 60 4100 060 O ring 84 x 4 mm 27 83005 U Cup 12 x 18 x 4 5 x 1 6 only with 3000 DVR 28 Fixing screw 29 60 3129 017 Riser pipe 250 mm long 30 60 3100 028 Serrated ring ZA 16...

Page 10: ...OPERATING MANUAL 3000 DV DVR V5 4 20 EN Page 10 14 Notices ...

Reviews: