background image

OPERATING MANUAL 3300 HSDR                                                                             V4.4/20-EN 

Page | 4 

 

Do not bring compressed air and/or medium into contact with 
skin or eyes. 

 

Never direct the spray jet at animals, people or yourself. 

 

Keep children and pets away from the operating area. 

 

No  manipulations,  emergency  repairs  or  misappropriations 
may be carried out on the pressure cup gun. 

 

Pressure cup guns may only be operated and maintained by 
instructed persons.  

 

Repairs must only be carried out by qualified persons. 
 

The following applies to all maintenance and repair work:

  

 

It  is  essential  to  disconnect  the  pressure  cup  gun  from  the 
compressed air connection before carrying out maintenance 
or repair work. 

 

Only use original spare parts. 

 

The  maximum  working  pressure  must  not  be  exceeded  (see 
point  1  "Technical  data").  The  working  pressure  must  be 
adjusted via a (filter) pressure reducer. 

 

Only use compressed air as energy source. 

 

The compressed air connection may only be made via a quick 
coupling. 

 

When working with the pressure cup gun, wear the necessary 
protective clothing, protective goggles, work gloves, ear pro-
tection if necessary and a respirator mask. 

 

If there are leaks in the device or other operating faults, the 
device must be disconnected from the compressed air supply 
immediately and the cause of the fault must be eliminated. 

 

Open fire, sparks or smoking is prohibited. 

 

Beware of flammable materials. 

 

Processed media and cleaning media must be disposed of in 
an environmentally friendly manner. 

 

The disposal of the compressed air device must be carried out 
according to the valid legal regulations. 

 

6.

 

Installation/ end of work 

Preparing the gun for the first start-up: Screw in the compressed air connection 
and tighten it firmly using a 13 mm open-end wrench or ring spanner, if  
necessary glue it in place.  

With  optional pressure regulator instead  of air volume regulation:

 Screw the 

pressure gauge included in the extent of delivery into the pressure regulator, if 
necessary glue it in. 
Start-up:  Unscrew  the  pressure  container  and  fill  the  medium  into  the  con-
tainer. Then hand-tighten the gun with the container cover onto the pressure 
container. Do not use any tools for this! Plug the connecting nipple of the hose 

Summary of Contents for 3300 HSDR

Page 1: ...OPERATING MANUAL 3300 HSDR V4 4 20 EN Page 1 Cavity sealing Pressure cup gun 3300 HSDR Art no 33001 33101 33102 33103 33104 ...

Page 2: ...erating manual with the pressure cup gun General notices This pressure cup gun was developed for certain applications We explicitly point out that this pressure cup gun must not be modified and or used in a way that does not correspond to its intended use Content 1 Technical data 3 2 Extent of delivery 3 3 Intended use 3 4 Features 3 5 Safety instructions 3 6 Installation end of work 5 7 Maintenan...

Page 3: ...mpressed air operated quality tool for professional use It is suitable for processing liquid media in the form of loose containers 4 Features The effectiveness of the 3300 HSDR pressure cup gun is based on overpressure For this purpose pressure is built up in the pressure container by means of an air duct integrated in the gun body This conveys the material present in the pressure container via a ...

Page 4: ... the necessary protective clothing protective goggles work gloves ear pro tection if necessary and a respirator mask If there are leaks in the device or other operating faults the device must be disconnected from the compressed air supply immediately and the cause of the fault must be eliminated Open fire sparks or smoking is prohibited Beware of flammable materials Processed media and cleaning me...

Page 5: ...e trigger while the container is under pres sure but the pressure cup gun is not connected to the com pressed air source This can push the medium into the air ducts and render the pressure cup gun unusable 7 Maintenance and care Clean the compressed air device after each use Fill the pressure tank with cleaning medium and flush the pressure cup gun and the hoses if present by starting the device W...

Page 6: ... initial position Possible cause The nozzle needle is jammed or dirty Solution Clean the nozzle needle apply oil to the nozzle needle and or slightly reduce the pressure on the nozzle needle seal using a 9mm wrench In order to ensure error free use a clamping effect on the nozzle needle seal must remain Press the trigger several times 10 Warranty terms The basis for all warranty claims is the comp...

Page 7: ... follow ing address Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach Germany Telephone 49 0 2774 80069 0 E Mail info vaupel gmbh de Internet www vaupel gmbh de Notice We reserve the right to make technical changes Illustrations may differ from the original We assume no liability for printing errors ...

Page 8: ...in accordance with the above EC Directives under the general responsibility of Company Vaupel GmbH Gerätebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The following harmonised standard has been applied DIN EN ISO 12100 Sicherheit von Maschinen Allgemeine Gestaltungsleit sätze Risikobeurteilung und Risikominderung The operating instructions...

Page 9: ...OPERATING MANUAL 3300 HSDR V4 4 20 EN Page 9 13 Notices ...

Page 10: ...OPERATING MANUAL 3300 HSDR V4 4 20 EN Page 10 14 Technical drawing ...

Page 11: ... O ring 5 x 1 mm 17 30 1421 012 Needle gland nut 18 60 4100 366 O ring 8 x 2 5 mm 19 30 2122 005 Nozzle head 20 20 1413 001 Quick coupling 21 see accessories list Cavity spray hose accessory 22 60 4100 371 O ring 15 x 2 mm 23 40 4104 014 Adapter 3000 24 25 60 4100 372 O ring 33 x 2 mm 26 10 2111 014 Cup holder 27 60 4100 344 U cup 12 x 18 x 4 5 x 1 6 28 60 4100 387 O ring 35 x 4 mm 29 30 83302 Fix...

Reviews: