background image

Vax Service line:   

AU: 1300 361 505 

NZ: 0800 800 900

vax.com.au

7

Operation

Using accessories

Attaching the hose

Attaching the telescopic extension tube

NOTE:

 The 3-in-1 tool and TurboTool can be attached to the telescopic tube or hose directly.

NOTE:

 The hard floor tool can ONLY be attached to the telescopic tube.

NOTE:

 To change setting on your 3-in-1 tool, press in the Vax logo located at the top of the tool.

Press the latch release on 
the hose before removing.

Remove telescopic 
extension tube.

Choose an accessory.

Attach hose to telescopic 
extension tube ensuring 
the latch secures the hose.

Choose an accessory.

Attach accessory to 
telescopic extension tube.

Attach accessory to hose 
ensuring the latch secures 
the accessory.

Hard floor tool can only be 
attached to telescopic tube.

Summary of Contents for Air Force VAFTHU

Page 1: ...model number What s your serial number Located on the base of the machine Note these down in case you need them in future Please keep instructions for further use vax com au VAFTHU User Guide Vax Careline AU 1300 361 505 NZ 0800 800 900 V A F T H U ...

Page 2: ...Vax Service line AU 1300 361 505 NZ 0800 800 900 v ...

Page 3: ... 9 Hose to machine connector 10 Height adjustment 11 Hose extension tube connector 12 Handle cord hook for attaching the cord when the machine is in use 13 Handle release button 14 Turbo tool caddy 15 Upper cord hook 16 3 in 1 crevice upholstery and dusting brush tool 17 Cord 18 Lower cord hook 19 Turbo tool 20 Hard floor tool 21 Pre motor filter 22 HEPA H12 antibacterial post motor filter PLEASE ...

Page 4: ... cord around sharp edges or corners Do not run the vacuum cleaner over the cord Keep the cord away from heated surfaces 11 Do not handle the plug or the vacuum cleaner with wet hands 12 Keep hair loose clothing fingers and all parts of the body away from openings and moving parts 13 Do not pick up any hot coals ash cigarette butts matches or any hot smoking or burning objects 14 Do not pick up any...

Page 5: ...er and cause overheating and permanent damage to the vacuum cleaner NOTE If the supply cord is damaged it must be replaced by the manufacturer or a similarly qualified person in order to avoid hazard or invalidating the warranty IMPORTANT The motor is equipped with a thermal cut out If for any reason the unit should overheat eg from blocked nozzles a full dust container or unclean filters the ther...

Page 6: ...ng them into the vacuum cleaner For full cleaning instructions see pages 8 and 9 IMPORTANT Do not use the vacuum cleaner without all of the filters in place IMPORTANT Even with regular cleaning filters have a limited lifespan and will eventually need to be replaced during the lifetime of the vacuum cleaner If the performance of your vacuum cleaner is compromised and or the filters are severely dis...

Page 7: ...low carpet pile IMPORTANT When the vacuum cleaner is stood in the upright position or when using the hose and tools the carpet height adjustment must be set to the high setting NOTE Vax recommends that you raise the height of the brushbar to the high setting when using this cleaner on lino and hard flooring due to constant rotation Vax cannot be held responsible for damage to these surfaces if the...

Page 8: ...e telescopic tube NOTE To change setting on your 3 in 1 tool press in the Vax logo located at the top of the tool Press the latch release on the hose before removing Remove telescopic extension tube Choose an accessory Attach hose to telescopic extension tube ensuring the latch secures the hose Choose an accessory Attach accessory to telescopic extension tube Attach accessory to hose ensuring the ...

Page 9: ...tainer Cleaning the HEPA pre motor filter IMPORTANT Water temperature should not exceed 40 C when washing the pre motor filter IMPORTANT Ensure the pre motor filter is completely dry before inserting back into the vacuum cleaner Tap to remove dirt and debris for a quick clean and before washing ...

Page 10: ...Vax Service line AU 1300 361 505 NZ 0800 800 900 v 9 Maintenance Keep your Vax as good as new Advanced filter cleaning Cleaning the post motor filter WARNING Do not wash the post motor filter ...

Page 11: ...ing checks Disconnect the hose from the vacuum cleaner and remove any blockages found then reconnect the hose securely Unscrew the 4 screws on the base of unit Slide off the locking ring Pivot lowering housing and remove clog To re assemble be sure that the tabs are engaged Pivot the lower housing closed Slip the locking ring into the groove at the neck of the Turbo Tool to complete reassembly Rem...

Page 12: ... may be blocked refer to Maintenance Emptying and cleaning the dirt container on page 8 The dirt container may be incorrectly installed remove the dirt container from the unit by pressing the dirt container release catch and then re attaching it to the unit ensuring it is locked firmly back into place What do I do if the unit an accessory becomes damaged or broken We re here to help Simply call us...

Page 13: ...For the nearest Service Agent please call the Vax Customer Careline or visit vax com au Technical Specification Voltage 220 240V 50Hz Wattage 1600W Capacity 4 Litres Filter Pre motor filter washable HEPA H12 antibacterial post motor filter tap to clean do not wash Cord length 10m Weight 8kg Subject to technical change without notice Waste electrical products should not be disposed of with househol...

Page 14: ...Distributed by Techtronic Industries Australia Pty Ltd Level 1 660 Doncaster Road Doncaster Australia 3108 www vax com au Service Line AU 1300 361 505 NZ 0800 800 900 ...