background image

www.vax.co.uk

10

general maintenance / troubleshooting

Pivot lower housing and remove clog (Fig.8/4).

To reassemble, be sure tabs are engaged. Pivot the lower
housing closed (Fig.8/5).

Rotate locking ring back round to secure.

9. Troubleshooting

WARNING:

To reduce risk of personal injury,

unplug vacuum cleaner before servicing.

PROBLEM:

Cleaner won’t run

Cause:

Not properly plugged into wall outlet.

Solution:

Plug in firmly.

Cause:

No electricity in wall outlet.

Solution:

Check fuse or breaker.

Cause:

On/off switch not turned on.

Solution:

Push on/off switch to on.

Cause:

Motor thermostat tripped.

Solution:

Switch off and unplug the vacuum cleaner.
Leave for one (1) hour. See page 3.

Cause:

Blown fuse/tripped breaker.

Solution:

Reset circuit breaker or replace fuse.

PROBLEM: Cleaner won't pick up

Cause:

Full or clogged dirt container.

Solution:

Clean dirt container.

Cause:

Clogged nozzle.

Solution:

Remove obstruction.

Cause:

Clogged dirt inlet.

Solution:

Remove suction channel cover and remove
obstruction.

Cause:

Clogged hose.

Solution:

Remove obstruction.

Cause:

Hose not inserted fully.

Solution:

Push hose in securely.

Cause:

Dirty filters or filter container.

Solution:

Clean/change filters or filter container.

PROBLEM: Accessories won't pick up

Cause:

Accessories not attached correctly.

Solution:

Refer to page 5 for fitting information.

PROBLEM: Brushbar does not turn

Cause:

Brushbar blocked.

Solution:

Remove blockages.

PROBLEM:

Air flow restricted with attachment use

Cause:

Attachment use restricts air flow.

Solution:

Check attachment.

Cause:

New carpet debris clogging air path.

Solution:

Remove obstruction.

Fig.8/4

TABS

Fig.8/5

!

Vax VZL-401AA Magnum User Guide.qxd:VZL-401 User Guide  11/3/09  09:59  Page 10

Summary of Contents for Magnum VZL-401AA

Page 1: ...antly rotating brush bar which when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brush bar when using this cleaner on lino and hard flooring Vax cannot be held responsible for damage to these surfaces if the customer fails to take notice of this recommendation Vax VZL 401AA Ma...

Page 2: ...xtension wand 18 On off pedal 19 Lower Cord Wrap 20 Handle Release Pedal 21 Upper hose 22 Power Cord 23 Lower Hose 24 Wheels Fig 1 1 3 2 1 4 8 9 10 11 13 12 5 6 21 22 23 24 15 14 16 19 18 20 17 7 VZL 401 WARNING This cleaner has a constantly rotating brush bar which when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax reco...

Page 3: ...xplosive liquids or vapours 13 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 14 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 15 Do not use without the filters in place 16 Take extra care when vacuuming on stairs 17 Keep vacuuming area well lit 18 Store the vacuum cleaner indoors in a cool dry area 19 Turn off the on off switch b...

Page 4: ...er to the desired setting Fig 4 2 NOTE The nozzle will not move into the adjusted position until the cleaner handle is lowered to the operating position On Off Switch Plug cord into electrical outlet Turn cleaner on by pressing the on off switch located on the lower back of unit Handle Release Pedal To release handle push the handle release pedal located on the lower left side of the cleaner Fig 4...

Page 5: ...hose from the base of the cleaner and the upper hose from the hose caddy Fig 4 6 Any of the accessories can be directly attached to the hose end or the end of the extension wand Fig 4 7 Simply push the attachment firmly onto the end of the extension wand To remove tool twist and pull apart gently Fig 4 8 The TurboTool is ideal for lifting pet hair off carpets stairs and upholstery The TurboTool is...

Page 6: ...hamber Replace central dust chamber bung and twist to secure Fig 5 4 Wipe inside of dust container and shroud with a damp cloth to remove excess dust Remove foam filter Press tab on bottom of foam filter cover and pull to remove Fig 5 5 Clean foam filter Separate the filter assembly by removing the foam filter from its plastic housing Tap the foam filter on the inside of a rubbish bin to remove ex...

Page 7: ...ss tab on exhaust filter and lift filter out of base of cleaner Fig 5 10 Clean exhaust filter Tap the exhaust filter on the inside of a rubbish bin to remove excess dust and dirt from filter Fig 5 11 Wash the exhaust filter under cold running water every 9 12 months Leave to dry for 24 hours before replacing in machine Replace exhaust filter Return exhaust filter to base of cleaner and snap into p...

Page 8: ...6 Belt or brushbar removal and replacement TOOL REQUIRED Phillips screwdriver WARNING to reduce the risk of injury from moving parts unplug cleaner before changing belt or brush To remove belt Lay cleaner flat and flip cleaner to expose nozzle base Fig 6 1 Base should lay flat and face up To remove nozzle guard use Phillips screwdriver to remove the SIX 6 screws Arrows show location of screws Fig ...

Page 9: ...move nozzle guard by removing the three 6 screws Remove obstructions Refer to Page 8 for belt and brushbar removal and replacement Debris removal Turbo Tool Rotate locking ring 180o and turn Turbo Tool over Fig 8 3 With new belt in place pull and slide brushbar into nozzle making sure that the brushbar end caps are in the correct orientation Fig 6 6 inset Rotate brushbar manually to make sure belt...

Page 10: ...eplace fuse PROBLEM Cleaner won t pick up Cause Full or clogged dirt container Solution Clean dirt container Cause Clogged nozzle Solution Remove obstruction Cause Clogged dirt inlet Solution Remove suction channel cover and remove obstruction Cause Clogged hose Solution Remove obstruction Cause Hose not inserted fully Solution Push hose in securely Cause Dirty filters or filter container Solution...

Page 11: ... serial number and model number of the carpet cleaner before calling There are over 400 approved Vax Service Agents in the UK For the nearest Service Agent please call the Vax Careline www vax co uk 11 Technical Specification Voltage 220 240V 50Hz Wattage 1400W Capacity 3 litres total 2 litres max fill Filters Foam pre motor Pleated HEPA exhaust filter Cord Length 6 75m Weight 7 36kg Subject to te...

Page 12: ...irective EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website www vax co uk Vax VZL 401AA Magnum User Guide qxd VZL 40...