background image

vax.co.uk

8

maintenance / troubleshooting

Remove the carpet height adjuster knob from the top of
the floor head cover. Remove the floor head cover, lifting
from the rear of the machine (Fig.7/3).

Remove the brushbar from the base, lifting from the right
hand side first (Fig.7/4).

Remove the worn or broken belt from the motor drive
shaft.

Carefully remove any belt residue that may exist in the belt
area before replacing with a new belt.

Loop the new belt first over the motor drive shaft and
then over the agitator pulley.

Insert the right side of the brushbar in first by placing the
end cap down in the slot and then so the same with the
left side. Press firmly to make sure that each end is
completely inserted.

Check to make sure that the belt is centred on the agitator
pulley and that the brushbar turns.

Replace the vacuum head cover then reattach the carpet
height adjuster knob. Secure parts by screwing in one (1)
screw underneath the small wheel flap and the five (5)
screws on the underside of the vacuum cleaner.

8. Troubleshooting

WARNING: To reduce the risk of personal injury,
unplug the vacuum cleaner before performing

maintenance or troubleshooting checks.

PROBLEM: Vacuum cleaner won't run
Cause:

Not properly plugged into electrical outlet.

Solution:

Plug in securely.

Cause:

No electricity in the electrical outlet.

Solution:

Check fuse or breaker.

Cause:

On/off switch not turned on.

Solution:

Push on/off switch to ‘on’.

Cause:

Motor thermostat has tripped.

Solution:

Switch off and unplug the vacuum cleaner.
Leave for one (1) hour before switching the
vacuum cleaner back on.

Cause:

Blown fuse/tripped breaker.

Solution:

Reset circuit breaker or replace fuse.

PROBLEM: Cleaner won’t pick up/loss of suction.
Cause:

Dirt container not installed properly.

Solution:

Review dirt container replacement.

Cause:

Dirt container full or blocked.

Solution:

Empty dirt container.

Cause:

Clogged filters.

Solution:

Remove, clean and replace filters.

PROBLEM: Accessories won’t pick up.
Cause:

Accessories are not attached correctly.

Solution:

Refer to section 5.

Cause:

TurboBrush / TurboTool is clogged.

Solution:

Refer to section 7.

Cause:

Hose / Stretch Hose is not installed correctly.

Solution:

Refer to section 7.

PROBLEM: Dust escaping from the vacuum cleaner.
Cause:

Dirt container full.

Solution:

Empty dirt container.

Cause:

Dirt container not installed correctly.

Solution:

Review dirt container replacement.

Cause:

Hose / Stretch Hose is not installed correctly.

Solution:

Review installation.

Cause:

Filter not installed completely.

Solution:

Remove, clean and replace filters.

!

Fig.7/3

Fig.7/4

Vax U91-P1 & 2 Series User Guide amend.qxd:User Guide  7/5/09  16:35  Page 8

Summary of Contents for Power 1 U91-P1 SERIES

Page 1: ...er has a constantly rotating brushbar which when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brushbar when using this cleaner on lino and hard flooring Vax cannot be held responsible for damage to these surfaces if the customer fails to take notice of this recommendation Vax ...

Page 2: ... release pedal 20 Two 2 short screws 21 Two 2 long screws 22 TurboTool U91 P1P U91 P2P only 1 2 14 15 16 10 5 12 13 22 22 17 6 9 3 4 7 8 20 21 WARNING This cleaner has a constantly rotating brushbar which when left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brushbar when using th...

Page 3: ...ts matches or any hot smoking or burning objects 13 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 14 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 15 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 16 Do not use without the filters in place...

Page 4: ...e dirt container push the top in place there will be an audible click when it is secure Fig 3 3 Assembly of the Hose Align the tabs on the lower hose inspection tube with the slots on the hose Push and turn the hose clockwise until secure Fig 3 4 Wrap the hose round and through the hose clip and then down and insert into hose connector Fig 3 5 Cord Storage This vacuum cleaner is equipped with a co...

Page 5: ...nob to the next highest setting until the vacuum is comfortable to push The brushbar must reach the carpet for effective cleaning Fig 4 3 IMPORTANT When the vacuum cleaner is stood in the upright position or when using the hose and tools the carpet height adjuster must be set to the highest position WARNING To avoid injury keep loose clothing hair fingers and all other parts of the body away from ...

Page 6: ...ilter in place To remove the dirt container press the dirt container release button and lift away from the vacuum cleaner Fig 6 1 Cleaning the HEPA Filter Remove the dirt container lid by grasping the dirt container and turning anti clockwise Fig 6 2 Empty all the dirt from the container Remove the filter by twisting anti clockwise and pulling out Firmly tap clean the HEPA filter until no more dus...

Page 7: ...strong detergents Ensure that the dirt container is fully dry before putting back on the vacuum cleaner Do not wash in dishwasher 7 Maintenance Cleaning and Changing the Belt TOOLS REQUIRED Phillips screwdriver WARNING To reduce the risk of electric shock the power cord must be disconnected before removing the dirt container HEPA filter changing the filters or performing maintenance troubleshootin...

Page 8: ... properly plugged into electrical outlet Solution Plug in securely Cause No electricity in the electrical outlet Solution Check fuse or breaker Cause On off switch not turned on Solution Push on off switch to on Cause Motor thermostat has tripped Solution Switch off and unplug the vacuum cleaner Leave for one 1 hour before switching the vacuum cleaner back on Cause Blown fuse tripped breaker Solut...

Page 9: ...are over 400 approved Vax Service Agents in the UK For the nearest Service Agent please call the Vax Careline vax co uk 10 Technical Specification Voltage 220 240V 50Hz Wattage 1600 1800W Capacity 2 9 litres approx Filters Pleated paper HEPA filter Pre motor HEPA antibacterial U91 P1P U91 P2P Cord length 7 4m approx Weight 6 6kg Subject to technical change without notice 9 Vax Careline 0870 606 12...

Page 10: ...vax co uk 10 This page has been left intentionally blank Vax U91 P1 2 Series User Guide amend qxd User Guide 7 5 09 16 35 Page 10 ...

Page 11: ...11 Vax Careline 0870 606 1248 This page has been left intentionally blank Vax U91 P1 2 Series User Guide amend qxd User Guide 7 5 09 16 35 Page 11 ...

Page 12: ...6 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk Vax U91 P1 2 Series User ...

Reviews: