background image

7

Vax Careline

0844 412 8455

accessories

2-in-1 Tool

Slide brush to remove. To replace brushes, align brushes,
align bottom of brush with grooves (A) on tool. Slide
brush into place (Fig.5/3).

Stair Cleaning

Use the hose and TurboTool for stair cleaning. Clean from
bottom to top

CAUTION: To avoid personal injury or
unnecessary wear to carpet, and to prevent

the cleaner from falling, always place it at bottom
of stairs.

Extra Reach Hose

(Some models only)

The Extra Reach hose provides easier cleaning of stairs
and hard to reach places.

Follow the steps below for attaching and detaching the
Extra Reach hose.

Turn cleaner OFF before disconnecting and connecting
hose. Remove hose end from dirt duct (A) (Fig.5/4).

Align end of Extra Reach hose with projections (B) over
slots on dirt duct (C). Slide hose into slots and twist hose
to lock it into place.

Align end of hose with projections (D) over slots (E) on
Extra Reach hose.

Slide hose into slots and twist hose to lock it into place
(Fig.5/5). (To detach hose, reverse procedure.)

Attach wands or tools to the other end of hose.

Note: Hose must be connected to dirt duct and hose
tube after removing Extra Reach hose for carpet or
floor cleaning.

Fig.5/4

Fig.5/5

A

A

B

C

D

E

Fig.5/3

!

U90-M7 Series User Guide.qxd:UG

16/9/09

15:37  Page 7

Summary of Contents for U90-M7 Series

Page 1: ... using this cleaner Always fully extend the mains cable before use Retain for future reference Vax careline 0844 412 8455 instruction manual Bagless upright Vax model number U90 M7 Series U90 M7 Series User Guide qxd UG 16 9 09 15 37 Page 1 ...

Page 2: ...ner from marking furniture 11 Brushbar shut off pedal 12 Brushbar shut off indicator 13 Exhaust filter access 14 2 in 1tool 15 TurboTool 16 Crevice tool 17 Hose tool holder 18 Extension wands 19 Cord reel 20 Soft Touch wheels 21 Handle release pedal step on lever to lower handle to operating or low positions 22 Cord rewind button press button to rewind cord for storage Hold plug until cord is rewo...

Page 3: ...y hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 13 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 14 Do not vacuum up hard or sharp objects such as glass nails screws coins etc 15 Do not use without the filters in place 16 Take extra c...

Page 4: ... base Fig 3 3 Position Tools Place smaller diameter end of wand A into bottom of holder Snap wand into clip at top Repeat with other wand Crevice tool B fits into one of the extension wands Fit 2 in 1 tool C into storage area on side of cleaner as shown Fig 3 4 Fit TurboTool A into recessed area on front of cleaner Pivot toward handle to snap in place Fig 3 5 Fig 3 1 Fig 3 2 Fig 3 3 Fig 3 4 Fig 3 ...

Page 5: ...om whipping hold plug until cord is rewound Transporting Cleaner To move your cleaner from room to room put handle in upright position tilt cleaner back on rear wheels and push forward Fig 4 4 Handle Positions The handle of your cleaner has three positions upright for storage and when using cleaning tools operating position for general operation on carpet and floors low for reaching under low furn...

Page 6: ...window Fig 4 8 5 Accessories Select proper tool Fig 5 1 A 2 in 1 tool use with brush for carved furniture table tops books lamps lighting fixtures venetian blinds skirting boards shutters and registers Remove brush Fig 5 3 to clean upholstered furniture mattresses clothing and carpeted stairs B TurboTool may be used for upholstered furniture mattresses clothing automobile interiors and carpeted st...

Page 7: ...Follow the steps below for attaching and detaching the Extra Reach hose Turn cleaner OFF before disconnecting and connecting hose Remove hose end from dirt duct A Fig 5 4 Align end of Extra Reach hose with projections B over slots on dirt duct C Slide hose into slots and twist hose to lock it into place Align end of hose with projections D over slots E on Extra Reach hose Slide hose into slots and...

Page 8: ... cause a reduction in performance When using the cleaner for this type of dust empty the cup and clean the filters often Press dirt cup release button A and pivot cup out Fig 6 2 Holding dirt cup over trash receptacle press dirt cup door release button A to open dirt cup door B Fig 6 3 Close door and press dirt cup door release button to latch dirt cup door closed Place bottom of dirt cup into cle...

Page 9: ... as previously described Fig 6 2 With thumb and forefinger slide latch A located at the top of the housing to the right and pull down to remove gray filter frame 9 Vax Careline 0844 412 8455 maintenance Remove black foam filter Rinse filter frame cartridge and foam filter under cold water Fig 6 8 Allow both filter frame and filter to air dry for 24 hours before replacing filter into filter frame R...

Page 10: ...are located under the bottom plate of the cleaner and should be checked from time to time to be sure they are in good condition Replacing Flat Belt Replace belt if it is stretched cut or broken To check the flat belt refer to Fig 6 13 Removing Bottom Plate Place handle in low position and turn cleaner over so bottom side is facing up Remove the 6 screws as shown with a Phillips screwdriver Lift of...

Page 11: ...44 412 8455 maintenance Reposition bottom plate and 6 Phillips head screws Tighten screws securely Fig 6 16 Inspecting V Belt The V belt is designed to last for a long time and is not normally replaced However if the V belt is cracked gouged or broken it should be replaced Slide flat belt off large pulley as shown in Fig 6 14 To remove V belt slide back of belt over pulley A Then firmly pull on be...

Page 12: ...reaker Cause Blown fuse tripped breaker Solution Reset circuit breaker or replace fuse Cause Motor thermostat tripped Solution Switch off and unplug the vacuum cleaner Leave for one 1 hour See page 3 PROBLEM Cleaner tools won t pick up Cause Broken or worn belt Solution replace belt Cause Brushbar worn Solution Replace brushbar Cause Dirt container full Solution Empty dirt container Cause Incorrec...

Page 13: ...Technical Specification Voltage 230 240V 50Hz Wattage 1500W Capacity 2 6L Filters Pre motor filter assembly HEPA post motor filter Cord Length 8 3m Weight 11 8kg Subject to technical change without notice U90 M7 Series User Guide qxd UG 16 9 09 15 37 Page 13 ...

Page 14: ...www vax co uk 14 This page has been left intentionally blank This page has been left intentionally blank This page has been left intentionally blank U90 M7 Series User Guide qxd UG 16 9 09 15 37 Page 14 ...

Page 15: ...15 Vax Careline 0844 412 8455 This page has been left intentionally blank U90 M7 Series User Guide qxd UG 16 9 09 15 37 Page 15 ...

Page 16: ...006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk U90 M7 Series User Guid...

Reviews: