background image

Page 3 / 4

170926

FIG.4 

           (View from Bottom of Back plate)

(Exterior Wall)

TIME

                         SENSITIVITY

TEST

0

3 6

5. Manual Override MODE (nighttime operation only; on at dusk, off at dawn) 

   

 

    In 3, 6 or 0 mode, to shift to manual override mode, turn off the wall switch in 3 seconds and then turn it on again, 

              the light will turn to high-level brightness at dusk, and turn off automatically at dawn. To return to the previous 

              settings, turn off the wall switch in 3 seconds and then turn it on again.  (See FIG.2)

       ●    The lights will turn off automatically at dawn.

Note: You can adjust the low level brightness (0~50%) by using the slide switch on the side of back 

          plate.(See FIG.3)

Shut-off Delay

The Shut-off delay is the length of time the light will stay at high-

level brightness after motion has ceased to be detected. This 

Shut-off delay can be set when operation is in 3, 6 or 0 Mode by 

using the “TIME” knob located on the left side of the panel at the 

bottom of the back plate (See FIG. 4) . To increase the shut-off 

delay, turn the knob clockwise. To decrease shut off delay, turn 

the knob counterclockwise. The delay may be adjusted from a minimum of 5 seconds to a maximum of 3 minutes. The 

light will stay on as long as motion is detected continuously and will automatically turn to low-level brightness when no 

more motion is detected after the delay time has passed.

Sensitivity of Motion Sensor 

The sensitivity of the motion sensor can be adjusted by using the “SENSITIVITY” knob located on the right side of the 

panel at the bottom of the back plate (See FIG.4). To increase sensitivity, turn the knob clockwise. To decrease 

sensitivity, turn the knob counterclockwise. The sensitivity may be adjusted from a minimum of 5 feet to a maximum of 

40 feet.

NOTE:

1. The sensitivity of the motion sensor will increase as the

    environmental temperature gets cooler. You may wish to

    make adjustments when the season changes.

    For best performance, gently clean the lens with a soft

    cloth every 1 or 2 months to assure maximum sensitivity.

2. For best performance, install fixture at least 6 feet above

    the ground. At such a height, the fixture will provide a

    detection distance of up to 40 feet at 77 degrees

    Fahrenheit. (See FIG.5)

3. The sensor detects across a detection range of 220 degrees. 

   (See FIG.6)

4. The sensor will be more sensitive to motion across its 

    detection path than motion directly towards it. (See FIG.7)

5. To reduce possible nuisances, do not mount the fixture 

    near a heat source like an air conditioner, vent or furnace 

    exhaust, or in a direction facing any reflecting object or 

    other light source.

CUSTOMIZATION OPTIONS:

5`

6`

10`

40`

FIG.5

Where you install your lantern is important:

Be sure the light is mounted straight on the wall; 

otherwise, the detection distance may be limited.

FIG.6

220'

Motion

Least sensitive

Motion

Most sensitive

Sensor

FIG.7

“3H Mode”

“6H Mode”

“0 Mode”

Manual

Override

Mode

Manual Override Operation Diagram

Turn wall switch OFF-ON 

in 3 Seconds

 

 

FIG.2

Turn wall switch OFF-ON 

in 3 Seconds again

FIG.3

 (View from one side of Back plate)

(Adjustable low level)