Installation Steps

Adjusting the Sensor Head: 

1. Aim sensor head toward desired detection area, maintaining a 

    5° - 40° downward angle to allow moisture to drain.

    Note: Make sure sensor head is positioned with control knob facing 

    towards the ground.

2. You can rotate the sensor head up and down to change the coverage 

    area. (See Fig. 1) 

    

Note: Range set too high may increase false triggering.

 

    (See Fig. 2 and Fig. 3)

Turn off the power at fuse or circuit box.

Turn on the power at the main fuse or circuit breaker box.

sensor

Fig. 1

Sensor

Backplate

Light Fixture

Fixture Mounting Screw 

Decorative cover 

Mounting Strap 

Outlet Box

Mounting Screw 

Mounting Bracket

FRONT

Page 2 / 7

1. The fixture mounting bracket is pre-assembled on the light fixture. Unscrew both the decorative cover and the fixture 

    mounting screw in order to remove the mounting bracket.

2. Install the mounting strap to the outlet box with the stamped word “FRONT” facing away from the outlet box, using two

    mounting screws that best fit the outlet box. Mounting bracket should sit flush against wall surface when secured. 

    (Choose one matching pair of suitable mounting screws from the 3 pairs provided).

3. Pull out the source wires from the outlet box.Connect the black wire from the outlet box to the "L" interface of the 

    terminal station on the mounting bracket. Connect the white wire from the outlet box to the "N" interface of the terminal  

    station on the mounting bracket. Carefully tuck the wires back into the outlet box.

4. Place mounting bracket against the outlet box, insert the mounting bracket screw through the mounting bracket hole,

    thread mounting bracket screw into the center hole of the mounting strap. Tighten the mounting bracket screw securely.

5. Attach the backplate of the light fixture to the mounting fixture mounting screw. Then push the decorative cover firmly 

    into the fixture mounting screw hole on the light fixture.

 

6. With silicone caulking compound, caulk completely around where the back plate meets the wall surface.

    CAUTION: Be sure to caulk completely where the back plate meets the wall surface to prevent water from 

    seeping into the outlet box.

 

211221

Summary of Contents for T0624

Page 1: ...al information about mounting location of fixture Light fixture and sensor should be mounted as shown above when installed depending upon type of installation Before installing the light fixture under...

Page 2: ...screws that best fit the outlet box Mounting bracket should sit flush against wall surface when secured Choose one matching pair of suitable mounting screws from the 3 pairs provided 3 Pull out the s...

Page 3: ...o warm up 1 TEST MODE daytime and nighttime operation Slide the Time switch the Test position The light turns to high level brightness 5000K when motion is detected and stays on as long as the motion...

Page 4: ...ing Network Setup From all the light units select one as the main unit and the others as the sub units First to setup all the sub units by press the Link button twice within 3 seconds the sub units wi...

Page 5: ...Sensor detects In Auto mode the lamp sends out a comprehensive signal to all the linked lamps to automatically switch to High Level brightness 5000K and remains on for predetermined time you set 30s...

Page 6: ...mproperly installed overloaded altered or otherwise abused by the customer its agent s or employee s Finishes are specially excluded from the terms of this warranty since they are subject to environme...

Page 7: ...rotection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructi...

Reviews: