Simplified Illustration of Operation of System Controller VC-SC1000M
- 3 -
5、
DVR/MULTI: Select the control protocol of DVR of Multiplexer.
DVR: Select the protocol for the current DVR.
Protocol of VC, HIK has been set up ex-work. Default protocol is HIK. If any other protocol of DVR is required. Please contact the supplier.
MULTI: Select the protocol of the current multiplexer. Default protocol is VC. If any other protocol of multiplexer is required. Please contact the supplier.
6、
Cam-PROT: Select the control protocol of camera.
Protocol of VC, Pelco-P, Pelco-D, Panasonic, Samsung has been set up ex-works.
If any other protocol of camera is required. Please contact the supplier.
7、
Set Baud Rate: Set up band rate of external communication for the controller. 5 kinds of baud rate from
1200BPS to
19200BPS can be selected. Default baud rate is 9600BPS.
NOTE: The a.m. setting will get into effect after restart. Other setting becomes effect.
8、
Set RF: Set up wireless alarm and relay.
Set Baud Rate:
9600 Save Off.Exit
Set DVR
:
P/D-Alarm:0001
Camera:0001 Monitor:001
Prepoint:001 OT:3 CT:3
On.Save Off.Exit CLR.INI
Alarm:0001
Cam Protocol: **
Baud Rate: 9600
On.Save Off.Exit
Alarm:0001
Relay Num: 001 002 003
004
On.Save Off.Exit
Press SET and enter protocol surface of link-alarm.
Press SHOT and enter relay surface.
Set Cam Protocol:
For All Camera: **
Camera: 0001 **
Save Off. Exit
All camera protocol
One camera protocol