Annex
101
VideoJet 100
LEDs
The VideoJet 100 is equipped with several LEDs which indicate the
operating status and can give indications of possible faults:
VIDEO
Lit green:
The video input is busy.
INPUTS
Not lit:
Alarm input inactive.
Lit green:
Alarm input activated.
Lit red:
Alarm triggered.
Change red/green: The program memory is being deleted (during
software upload). The programming progress is
indicated by the alternating green lighting up of
all five LEDs.
OUTPUTS
Not lit:
Output inactive (rest state).
Lit green:
Output switched.
COM
Flashing green:
Data transmission via serial interfaces.
ETHERNET
Lit green:
Physical connection to the network established.
Flashing yellow:
Data transmission via the network.
POWER
Not lit:
VideoJet 100 switched off.
Lit green:
VideoJet 100 switched on, no connection.
Flashing green:
600 ms (50:50) = 1 active connection
300 ms (50:50) = 2 active connections
150 ms (50:50) = 3 or more connections
Green flash:
(50:650) = Streaming mode is active
Green flash:
70 ms (50:50) = External prompt, e.g. via the
VCS JetManager