background image

5

9.

 For a new coil, twist tip 

1

/

2

 turn to fully saturate wick. Otherwise, each 

1

/

4

 turn of mouth tip excretes a sufficient dab of material for 4-8 draws. 

10.

 Thread base onto BATTERY 

7

. Press power button five times to turn 

on/off. Verify coil function. (See page 9 for more on BATTERY)

11.

 Press sleeve firmly onto base. 

6.

 Twist plunger handle slowly until a small dab protrudes from chamber. 

7.

 

Rub a touch of food-grade oil onto PLUNGER

 

2

 and BASE

 

5

 o-rings.

 

8.

 Align mouth tip onto plunger handle and push down until it fits tight. 

Watch through sleeve for small 

dab to protrude from chamber 

while twisting plunger handle 

Twist clockwise

Summary of Contents for EverSmooth

Page 1: ...User Guide ...

Page 2: ...Table of Contents R E A D C O M P L E T E L Y B E F O R E U S E PARTS LIST 1 OUR STORY 2 LOADING YOUR Vdab200 3 USE 6 TIPS 7 CARE 8 BATTERY 9 WARRANTY RETURNS and DISCLAIMER 10 CONTACT US 11 ...

Page 3: ...erials harden much like cement when cold Forcing the plunger 2 out can leave behind the plunger s plastic tip But if this happens don t fret Warm load chamber 3 and use back end of scoop 10 to push out plastic end Contact us for a replacement tip at www vdab200 com ...

Page 4: ...1 8 USB Charger PARTS LIST 6 Base 2 Plunger 1 Mouth Tip 3 Load Chamber 5 Dual Coil 10 Scoop 7 510 vv Battery 9 Tamper 4 Sleeve 11 Stand Bonus Parts 2 spare dual coils 2 spare O rings ...

Page 5: ... a discreet hassle free EverSmooth experience Just push the button and go We hope you love it as much as we do Part Numbers 1 4 and 9 listed on page 1 comprise the patent pending Vdab200 atomizer and tamper These devices are made of surgical grade stainless steel with great care in the USA Warranty Parts 1 4 and 9 come with a lifetime warranty from material defects not including o rings and plunge...

Page 6: ...rew sleeve from plunger Pull LOAD CHAMBER 3 from sleeve 2 Prepare and Load Material A Roll 3 8 square of cold material into a firm cylinder and load into LOAD CHAMBER 3 Tip A few minutes in the freezer will harden material to optimum consistency B Use SCOOP 10 to load ewax or essentials that will not roll The Vdab200 is not for use with oils Load Material into Load Chamber ...

Page 7: ...vent sticking Continue adding material up to 1 4 from top Do not fill above tamper groove Compress until you see material at the end of load chamber tip Avoid air bubbles Compress Material with Tamper Load Chamber Tip Open end of sleeve Max Fill Groove 4 Place load chamber into sleeve 5 Thread sleeve onto plunger and observe open end of sleeve ...

Page 8: ...o turn on off Verify coil function See page 9 for more on BATTERY 11 Press sleeve firmly onto base 6 Twist plunger handle slowly until a small dab protrudes from chamber 7 Rub a touch of food grade oil onto PLUNGER 2 and BASE 5 o rings 8 Align mouth tip onto plunger handle and push down until it fits tight Watch through sleeve for small dab to protrude from chamber while twisting plunger handle Tw...

Page 9: ... not overload coil 3 The load chamber is empty when tip no longer turns See CARE to refill 4 It is best to leave load chamber closed until empty To extract material for other uses heat Vdab for a few seconds then carefully remove sleeve from base see TIP 2 Twist mouth tip to excrete material Use scoop to scrape material off load chamber tip Twist clockwise ...

Page 10: ...ween the coil and chamber tip We suggest an only when needed approach 3 The Vdab works better in a more vertical position This allows material to melt down onto the coil and for vapor to draw 4 It won t work if you tip the battery end up The material flows backward and can even seep between the load chamber and the sleeve We call this melt back 5 To avoid melt back let wax cool a few seconds befor...

Page 11: ... if it does not extract easily 5 Use nipple end of tamper to push remaining material out Tip Rub a touch of oil on tamper to prevent sticking 6 Clean your Vdab with alcohol and allow to dry completely before reuse Tip Wipe outside or soak for thorough clean 90 or greater isopropyl alcohol is best 7 For longer wear reapply a touch of oil to o rings on plunger and base after each cleaning Oil o ring...

Page 12: ... to 4 8v to your preference using the bottom Click mechanism that prevents surprise setting changes 4 The power level indicator on the power button is a great feature to avoid overloading the coil and for maintaining performance A 100 50 power light is white B 50 10 power light is blue C 10 0 power light is red 5 Remove battery from base to recharge Wethinkyou lllovetheClick battery manufacturedby...

Page 13: ... original manufacturer We are not liable for defects however should the battery or base fail during the first 90 days contact us for replacement Returns All returns and exchanges are made according to return policy found on www vdab200 com or as otherwise stated herein Disclaimer Organic materials react differently to heat QanTeq Inc is not responsible for consumer s actions or for the reaction of...

Page 14: ... com to order replacement parts coils and accessories and to find out more about the Vdab200 Follow us on Twitter vdab200 Watch our instruction video Youtube channel vdab200 For further information about the Click battery see www c tratech com Sincerely EverSmooth the Vdabbers ...

Page 15: ...PO Box 10788 Zephyr Cove NV 89448 ...

Reviews: