70
DTCO 1381
Overview of the faults
7. Messages
7
쮿
Overview of the faults
If a fault repeats on a continuous basis, please contact an authorised
workshop.
Picto / reason
Meaning
Measure
x
internal
fault
Serious fault in the DTCO 1381, the following are possible
causes:
앫
Unexpected program faults or processing time faults.
Acknowledge message.
앫
Button elements blocked or pressed simultaneously for
some time.
Check proper function of the button ele-
ments.
앫
Communication fault with external devices.
Check connecting cables or function of the
external devices.
앫
Communication fault with the instrument display.
Check connecting cables or function of the
instrument display.
앫
Fault at pulse output.
Check connecting cables or function of the
connected control device.
x
1 internal
fault
앫
Fault in the card mechanics, e.g. card lock is not closed.
Remove tachograph card and insert it again.
x
time fault
UTC time of the DTCO 1381 is not plausible or does not function
properly. In order to avoid an inconsistency of data, newly
inserted driver / company cards are not accepted!
Acknowledge message.
x
printer
fault
The printer's supply voltage has failed or the temperature sensor
for the printing head is defective.
Acknowledge message.
Repeat the process and, if necessary, switch
off / on the ignition again.
Service
only
Summary of Contents for DTCO 1381
Page 42: ...42 DTCO 1381 4 S e r v i c e o n l y...
Page 108: ...108 DTCO 1381 9 S e r v i c e o n l y...
Page 113: ...Appendix Notes Continental Automotive GmbH 113 A Notes S e r v i c e o n l y...
Page 114: ...114 DTCO 1381 Notes Appendix A S e r v i c e o n l y...
Page 115: ...Continental Automotive GmbH 115 S e r v i c e o n l y...