INSTALLATION INSTRUCTIONS: Viewline 85 mm

TU00-0752-5807102

Technische Änderungen vorbehalten  -  Technical details subject to change

TU00-0752-5807102

Tachometer

Depending on the configuration, insert the cable into the 8-pin and 14-pin con-

tact housing according to the following pin assignment. The contacts must

audibly lock into place.

8-pin contact housing 

14-pin contact housing

Pin 1 - Term. 30 - battery 12/24 V 

Pin 1 - unassigned

Pin 2 - Term. 31 - ground 

Pin 2 - unassigned

Pin 3 - signal ground 

Pin 3 - unassigned

Pin 4 - Term. 15 - ignition plus 

Pin 4 - unassigned

Pin 5 - sensor signal 

Pin 5 - unassigned

Pin 6 - Term. 58 - lighting 

Pin 6 - unassigned

Pin 7 - programming port Tx  

Pin 7 - unassigned

Pin 8 - programming port Rx 

Pin 8 - unassigned

 

Pin 9 - unassigned

 

Pin 10 - unassigned

 

Pin 11 - Configuration key

 

Pin 12 - Mode key

 

Pin 13 - Alarm output (max 100 mA)*

 

Pin 14 - unassigned

 

see wiring diagram on last page

Place the flush mount seal A2C53215641 on the 

instrument glass. 

Put the instrument into the drill hole from the back.  

Adjust the instrument so that the gauge is level and 

fasten it to the stud bolts on the rear side of the panel, 

using the flush mount fixing bracket A2C59510864.

If the instrument is mounted flush (i.e., from the back 

so that the instrument glass and the panel form one 

plane), the front ring must be removed. Press the 

instrument glass with both thumbs, while at the same 

time pressing the front ring forward from the instrument 

with both index fingers. Note the use of a tool  

in the adjacent figure.

Flush assembly.

The recommended panel thickness is 1.5 to 3 mm.  

The drill hole must have a diameter of 75.4 mm. 

Ensure that the installation location is level and has  

no sharp edges. 

1.5...3 mm

dia. 75.4 mm

  Do not drill holes or ports in load-bearing or stabilizing stays or tie bars! 

  Note the necessary clearance behind the drill hole or port at the installation location. Required mounting depth: 

65 mm. 

  Drill small ports; enlarge and complete them, if necessary using taper milling tools, saber saw, keyhole saw or 

file. Debur edges. Follow the safety instructions of the tool manufacturer.

Now insert the plug into the gauge. Note the inverse 

polarity protection nose in the process.

Summary of Contents for TU00-0752-5807102

Page 1: ...nical and electrical airbag area Do not drill holes or ports in load bearing or stabilizing stays or tie bars When working underneath the vehicle secure it according to the specifications from the veh...

Page 2: ...ion Required mounting depth 65 mm Drill small ports enlarge and complete them if necessary using taper milling tools saber saw keyhole saw or file Debur edges Follow the safety instructions of the too...

Page 3: ...into the drill hole from the back Adjust the instrument so that the gauge is level and fasten it to the stud bolts on the rear side of the panel using the flush mount fixing bracket A2C59510864 If th...

Page 4: ...ducing the cable cross sectional area leads to higher current density which can cause the cable cross sectional area in question to heat up When installing electrical cable use the provided cable duct...

Page 5: ...nut is not tightened with a torque greater than 400 Ncm Make sure the seal lays flat between the panel and the front ring If you would like to omit the fastening nut you may use the part set A2C59510...

Page 6: ...tting the impulse number 1 Activate T 30 8 pin Pin1 2 Deactivate T 15 8 pin Pin4 3 Press and hold Config key 14 pin Pin 11 Activate T 15 Release Config key Press and hold Config key Set impulse number...

Page 7: ...y you can switch between 24h and 12h AM PM clock format Press and hold Mode key Press Mode key briefly Press and hold Mode key Set alarm threshold is displayed the first digit flashes Press Mode key b...

Page 8: ...lay indicator selection 1 Activate T 30 8 pin Pin1 2 Activate T 15 8 pin Pin4 Press Mode key briefly Press Mode key briefly Press Mode key briefly 2 Resetting the day counter 1 Activate T 30 8 pin Pin...

Page 9: ...s to 0 Press and hold Mode key The next lower digit flashes Press Mode key briefly The flashing digit increases by 1 If the flashing digit is 9 the display returns to 0 Continue until the correct time...

Page 10: ...gle contacts 0 14 0 22 mm Tyco No 1355718 1 Single contacts 0 5 0 75 mm Tyco No 963729 1 Strip 0 14 0 22 mm Tyco No 1355717 1 Strip 0 25 0 5 mm Tyco No 928999 1 Strip 0 5 0 75 mm Tyco No 963715 1 Brac...

Page 11: ...r signal Green 6 Lighting Positive Blue Red 7 Warning LED ground Yellow Black 8 Warning LED plus Yellow Red Please read instructions included as some of these pins will not be required Programming Por...