Viewline Pressure gauges
Technische Änderungen vorbehalten
12/09
Technical details subject to change
2 - 6
The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express
authorization is prohibited. Offenders will be held liable for the payment of damages. All right reserved in the event of the grant of a patent,
utility model or design
.
Technical Data
Installation depth
50mm
Installation diameter
52mm
Deflection angle
90°
Operating Voltage
10 – 16 Volt
Accuracy
< 3,6 angular degrees
Current consumption
< 140 mA, including Warning LED
Operating temperature
-30°C to +80°C; plated bezels (chrome) -30°C to +70°C
Storage temperature
-40°C to +80°C for 48h; plated bezels (chrome) -40°C to +70°C
+90°C for 1h
Temperature shock
Range
-40°C to +85°C; plated bezels (chrome) -40°C to +70°C
Transformation time
10 seconds
Retention
time
2h
Climatic test
Range
+25°C to +55°C
Rel.
Humidity
95%
EMC in conformity with
DIN_EN 61000-6-3
DIN_EN
61000-6-1
DIN_EN
61000-6-4
DIN_EN
61000-6-2
Standards EN
60945
GL, Category C, F (under preparation)
Vibration
Sinus 2g; 10-500Hz; duration 16h
Noise 3g; 10-1000Hz, duration 8h
Mechanical shock
continuous
25g; 6ms; 1Hz
Single shock
100g; 11ms
Free fall
1m; 3 times
Chemical resistance against - preservative agent
- preservative agent remover
- cold cleaner
- methylated spirit
- interior cleaner
- drinks containing caffeine and tannin
Nominal position
NL 0 to NL 85 (DIN16257)
Protection class
according to IEC 60529
Front: IP67 (in Nominal position)
Rear: IP52 (in Nominal position)
Reverse polarity protection yes, 5 minute
Over voltage protection
yes, 24V for1 minute