background image

 

Viewline Pressure gauges

 

 

Technische Änderungen vorbehalten

 12/09 

Technical details subject to change

 

2 - 6 

 

The reproduction, distribution and utilization of this document as well as the communication of its contents to others without express 
authorization is prohibited. Offenders will be held liable for the payment of damages. All right reserved in the event of the grant of a patent, 
utility model or design

 

 

Technical Data  

Installation depth 

50mm 

 
Installation diameter 

52mm 

 
Deflection angle 

90° 

 
Operating Voltage  

10 – 16 Volt 

 
Accuracy  

< 3,6 angular degrees 

 
Current consumption  

< 140 mA, including Warning LED 

 
Operating temperature 

-30°C to +80°C; plated bezels (chrome) -30°C to +70°C 

 
Storage temperature 

-40°C to +80°C for 48h; plated bezels (chrome) -40°C to +70°C 

 

+90°C for 1h 

 
Temperature shock 

Range 

-40°C to +85°C; plated bezels (chrome) -40°C to +70°C 

 

Transformation time  

10 seconds 

 Retention 

time 

 

2h 

 
Climatic test 

Range 

+25°C to +55°C  

 Rel. 

Humidity 

95% 

 
EMC in conformity with 

DIN_EN 61000-6-3 

 DIN_EN 

61000-6-1 

 DIN_EN 

61000-6-4 

 DIN_EN 

61000-6-2 

 
Standards EN 

60945 

 

GL, Category C, F (under preparation) 

 
Vibration 

Sinus 2g; 10-500Hz; duration 16h 

 

Noise 3g; 10-1000Hz, duration 8h 

 
Mechanical shock 

continuous 

25g; 6ms; 1Hz 

 

Single shock 

100g; 11ms 

 

Free fall 

1m; 3 times 

 
Chemical resistance against - preservative agent 
 

- preservative agent remover 

 

- cold cleaner 

 

- methylated spirit 

 

- interior cleaner 

 

- drinks containing caffeine and tannin 

 
Nominal position 

NL 0 to NL 85 (DIN16257) 

 
Protection class  

according to IEC 60529 

 

Front: IP67 (in Nominal position) 

 

Rear: IP52 (in Nominal position) 

 
Reverse polarity protection  yes, 5 minute 
 
Over voltage protection 

yes, 24V for1 minute 

Reviews: