background image

1.

Some parts of the appliance can become very hot and cause burns.
Particular attention has to be given where children and vulnerable people are present.

2.  This appliance may be used by children aged 8 years or above, people with physical and

mental disabilities, as well as those who lack any experience, provided that they have
received detailed instructions about the functionality of the appliance and any risks.
Children must not play with the appliance.  Cleaning and maintenance must not be
performed by children without proper supervision. Children under 3 years of age should
not be near the appliance without constant supervision.
Children between 3 and 8 years old may only turn on/shut off the appliance, if it is
located in a suitable position and they have received instructions about the proper
course of action, or are being supervised.
They shall also be informed about possible dangers.
Children between 3 and 8 years old may not connect the device, change its settings or
perform care/maintenance.

3.  All installation work must be carried out by a qualified technician.
4.  The appliance

, are approved for use in dry, damp or wet rooms,

but not in environments where there is a risk of fire or explosion.

5.

WARNING !

EA

The heater must be connected to the mains supply with a fixed installed cable,

which ensures that the electrical protection class of the heater is retained.

6.  An all-phase breaker must be included in the fixed installation.
7.  The heater must not be located immediately below a socket outlet.
8.  The heater is S-marked, CE-marked, EMC-marked and designed in accordance with the

following standards:

6

CAUTION: Read this manual before using the product.
Save the manual for future use.

Safety information

EN

EA

> 1800 mm

> 300 mm

> 300 mm

> 300 mm

> 1800 mm

> 2500 mm

> 2500 mm

W

H

D

A

B

> 1800 mm

> 300 mm

> 300 mm

> 1800 mm

Mounting

1.  The heater brackets are to be fastened to the wall or to the ceiling with screws.

The distances shown in the above sketch are minimum.
Distances less than shown may cause fire.

2.  The connection box must always be positioned upwards.
3.  The heater must not be covered or tampered, to avoid overheating, fire or electric shock.

EN 60335-1 / EN 60335-2-30 / EN 61000-6-1 / EN 61000-6-2 / EN 61000-6-3 / EN 61000-6-4.

Summary of Contents for EA

Page 1: ...ische Heizl fter Typ ACHTUNG Handbuch f r zuk nftigen Gebrauch aufbewahren EA Lesen Sie dieses Handbuch bevor Sie das Ger t montieren anschliessen und in Betrieb nehmen MANUEL Ventilateur lectrique ty...

Page 2: ...och beh rig personal 4 Produkterna i serien r godk nda f r anv ndning i torra och fuktiga rum samt i v trum men inte i brandfarliga eller Ex klassade utrymmen VARNING EA 5 V rmaren m ste anslutas til...

Page 3: ...st r i l ge eller OK2 Alternativ 1 Extern elektronisk termostat OCC4 OCD4 med adaptiv reglerfunktion Kopplingsplintarna och byglas 17 20 Alternativ 2 V rmarens inbyggda elektroniska termostat anv nds...

Page 4: ...10VDC 2 10VDC Slavv rmarna kaskadkopplas med 0 10VDC och signalkabelns l ngd mellan v rmarna f r vara max 16m EA EA EA Slav 1 Master Slav 2 Slav 18 18 18 26 26 26 19 19 19 27 27 27 17 17 17 25 25 25 2...

Page 5: ...pparna Upp och Ner och bekr fta med OK St ll in timmar och minuter och bekr fta med OK St ll in r m nad och dag och bekr fta med OK Nu r termostaten klar att anv ndas Den kommer att styra din v rme en...

Page 6: ...l installation work must be carried out by a qualified technician 4 The appliance are approved for use in dry damp or wet rooms but not in environments where there is a risk of fire or explosion 5 WAR...

Page 7: ...external function switch is in position or OK2 Alternative 1 External electronic thermostat OCC4 OCD4 with adaptive control function Terminals and must be linked 17 20 Alternative 2 The heater built i...

Page 8: ...an be controlled either by the OCC4 OCD4 NTC sensor or by a 0 10VDC 2 10VDC excitation voltage The slave heaters are cascaded by the 0 10VDC voltage and the excitation cable length from one heater to...

Page 9: ...th the Up and Down buttons and confirm with OK Set the hours and minutes and confirm with OK Set the year month and day and confirm with OK The thermostat is now ready for use and will control your he...

Page 10: ...e sind f r den Einsatz in trockenen feuchten oder nassen R umen zugelassen jedoch nicht in Umgebungen in denen ein Brandrisiko oder eine Explosionsgefahr besteht 5 Ger te ACHTUNG Die sind mit fest ver...

Page 11: ...nd stoppt wenn der W rmebedarf gedeckt ist erlischt sofern sich der Schalter in Stellung oder befindet OK2 Alternative 1 Externer elektronischer Thermostat OCC4 OCD4 mit adaptiver Steuerfunktion Die K...

Page 12: ...gte kann entweder mit OCC4 OCD4 TG R430 oder 0 10VDC 2 10VDC angesteuert werden Die nachgesteuerten werden in Reihe nacheinander mit 0 10 VDC angeschlossen und die Signalkabell nge darf zwischen den G...

Page 13: ...re Sprache und mit OK best tigen Die Stunde und die Minuten einstellen und mit OK best tigen Jahr Monat und Tag einstellen und mit OK best tigen Der Thermostat ist jetzt betriebsbereit und steuert Ihr...

Page 14: ...s ries sont destin s l usage dans des pi ces s ches ou humides ainsi que dans des pi ces d eau mais non dans des espaces pr sentant un risque d incendie ou d explosion 5 ATTENTION EA Le ventilateur d...

Page 15: ...age cesse condition que le commutateur soit en position ou OK2 Alternative 1 Thermostat lectronique externe OCC4 OCD4 avec fonction de contr le adaptatif Les bornes de raccordement et sont pont es 17...

Page 16: ...oit avec OCC4 OCD4 TG R430 ou 0 10VDC 2 10VDC Les r chauffeurs esclaves sont mont s en cascade avec 0 10VDC et la longueur du c ble de signal entre les r chauffeurs peut tre de 16m maximum EA EA EA Le...

Page 17: ...c les touches Haut et Bas et confirmez avec OK R glez les heures et les minutes et confirmez avec OK R glez l ann e le mois et le jour et confirmez avec OK Le thermostat est maintenant pr t tre utilis...

Page 18: ...valtuutettu ammattilainen 4 sarjan tuotteet on hyv ksytty k ytett v ksi kuivissa ja kosteissa huoneissa sek m rk tiloissa mutta ei palovaarallisissa tai Exluokitelluissa tiloissa 5 VAROITUS EA Kiuas o...

Page 19: ...yttyy lakkaa jos kytkin on asennossa tai OK2 Vaihtoehto 1 Ulkoinen elektroninen termostaatti OCC4 OCD4 mukautuvalla ohjaustoiminnolla Liit nt liittimet ja on silloitettu 17 20 Vaihtoehto 2 Kiukaan sis...

Page 20: ...0 10VDC ja signaalikaapelin pituus l mmittimien v lill saa olla enint n 16m EA EA EA Orja 1 P l mmittimen Orja 2 Orja 18 18 18 26 26 26 19 19 19 27 27 27 17 17 17 25 25 25 20 20 20 28 28 28 EA Useide...

Page 21: ...painikkeilla ja vahvista painamalla OK Aseta tunnit ja minuutit ja vahvista painamalla OK Aseta vuosi kuukausi ja p iv ja vahvista painamalla OK Termostaatti on nyt k ytt valmis Se s telee l mp si vas...

Page 22: ...22 EA...

Page 23: ...23 EA...

Page 24: ...die Broschure ohne Mitteilung entwickeln und oder verandern Ce document peut contenir des diff rences techniques ou des fautes d impression VEAB Heat Tech AB est habilit d velopper et ou modifier les...

Reviews: