6
LAF
General
The dehumidifier is portable and is designed for dehumidifying various premises. The dehumidifier has been approved for damp and
wet areas, and is used for applications such as building sites, industrial premises, warehouses, and in the home.
Dehumidifiers designated LAF 50ES to LAF 150E have built-in heaters. The dehumidifier has been subjected to electrical
safety and EMC tests by the Swedish Board for Testing and Approval of Electrical Equipment (SEMKO). The dehumidifier is CE
marked. Degree of protection: IP X4 (corresponds to splash-proof). Dehumidifier LAF 50 is stackable, at a height of two, for storage
on the floor.
Before commissioning
LAF 50S, 50ES and 50E2S are delivered without mounted console. This must be installed prior to commissioning.
See installation instructions, Appendix 1.
Safety
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person
responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
• Locate the dehumidifier on a stable and level surface so that it will not overturn.
• The dehumidifier must not be covered over, since this may cause overheating and give rise to the risk of fire (see also Fig. A)
• The different models of LAF 50 are stackable, at a height of two, when stored on floors. The dehumidifier must not be
transported or rolled in stacked position.
Fig. A
Fig. B
Use and operation of the LAF 50, LAF 100 and LAF 150
Location and condensate disposal
Ambient temperature operating range: +3°C to +30°C
Ambient humidity operating range: 30 to 100% RH
If the dehumidifier has been stored at a temperature lower than the ambient, it should be allowed to assume ambient temperature
before it is started. After it has been switched off, the dehumidifier must not be restarted earlier than within 10 minutes.
1. Locate the dehumidifier in the centre of the premises, on a surface that is not sensitive to water.
2. Shut the doors, windows, vents, etc., so that the premises will be as tight as possible. Maintain the highest possible ambient
temperature to ensure maximum dehumidification.
3. The condensate collecting container of the dehumidifier has a built-in level switch that will stop the dehumidifier when the
container is full. This is indicated by an LED lighting up with a steady light. The condensate can also be discharged through a
hose directly to drain. A 1/2” hose should be connected to the tube with a hose clip above the container (see Fig. B).
A collecting container with pump is also available as an option.
4. When the collecting container has been removed, the dehumidifier will restart. Empty the container and place it back in
position as quickly as possible.
GB