• Always request original spare parts for repairs
• If the product needs to be removed, turn off the

mains supply circuit-breaker and then discon-
nect the fan.

• The fan 

MUST BE

installed as detailed in 

this leaflet

WARNING:  Damage  could  be  caused  to  the
product  if  the  installation  instructions  are  not
followed 

• The product should 

not

be used in an ambient 

temperature higher than 40°C (104°F).

• The product should 

not

be exposed to atmos-

pheric agents (rain, sun, snow, etc.).

• The product or its parts should 

not

be 

placed in water or other liquids.

• Routine maintenance as described below 

should be carried out to check the condition of 
the fan.

• The air or fumes being extracted must be clean

and free from greasy particles, soot, chemical 
and corrosive agents, flammable or explosive 
mixtures. 

The product must be installed by profes-
sionally qualified personnel. Incorrect 
installation can cause damage to people, 
animals or property, for which the manufac-
turer cannot be held liable.

• The product must be connected to the electrici-

ty supply via a double pole switch of a suitable 
size, with contact openings of at least 3 mm.  

• If the electrical supply board (or switching 

device) is located some distance from the fan a
means of local isolation must be provided.

• To ensure optimum operation, do not block the 

air intake and exit vents. 

• Any ducting used must be free of blockages.
• The room where the product is operating must 

have adequate air replacement to ensure maxi-
mum effectiveness.

• If the product is sited in a room containing a 

fuel burning appliance which is not of the bal-
anced flue type, the installer must ensure that 
air replacement is adequate both for the fan 
and the fuel burning appliance. 

• The product must 

not

be used as an activator 

for water heaters, stoves, etc.

• The product must 

not

exhaust into ducts 

designed to evacuate fumes from combustion 
in stoves or other combustion-powered 
devices.

RANGE

ES1003 

- this fan combines the latest technology

with energy saving and efficiency.  It is a quiet
running, 3 speed fan.  It is designed to run 
continuously at a pre-selectable choice of 2 lower
speeds (fixed at installation).  The user can boost
the fan speed to its maximum performance when
required by means of the cord or remove the cord
and use a remote switch, light switch, PIR sensor
or humidistat.  

The ES1003 is SAP Appendix Q

Listed

.

ES1003CF - 

as above, but complete with metal

filter.

ES100H2C 

- humidity control model - the fan will

start to operate automatically at its lower speed
when the relative humidity reaches the pre-set
level and will continue to operate at this speed
until the humidity has been dispersed.  The user
can use the cord or the remote switch (if the cord
has been removed) to operate the fan (at its high-
er speed), or boost the fan speed if it is already
running.  Pulling the cord again (or switching off)
will revert the fan to its lower speed, and it will
continue to run either until the humidity has been
removed, or the fan has completed the timer
over-run period (adjustable between 3 and 25
minutes).  The fan's "

comfortimer

” technology

3

Summary of Contents for eSmile

Page 1: ...continuous running with or without filter humidity control SELV low voltage 3 speed continuous running humidity control for all domestic wet rooms for walls or ceilings IPX4 IPX7 쓑 The Carbon Friendly Fan Installation and Operating Instructions ...

Page 2: ...ct before doing this Do not leave packing material within the reach of children or unskilled people To dispose of the packaging and the appliance at the end of its useful life refer to the recycling norms in force The use of any electrical product requires compliance with some basic rules which are listed below do not touch it with wet or damp parts of the body e g hands feet this appliance can be...

Page 3: ...replacement to ensure maxi mum effectiveness If the product is sited in a room containing a fuel burning appliance which is not of the bal anced flue type the installer must ensure that air replacement is adequate both for the fan and the fuel burning appliance The product must not be used as an activator for water heaters stoves etc The product must not exhaust into ducts designed to evacuate fum...

Page 4: ...ws the fan to run at low speed for its over run period The humidistat is adjustable from 40 to 90 relatve humidity ES1003CLV 12v SELV version of ES1003 ES100H2CLV 12v SELV version of ES100H2C 4 INSTALLATION ...

Page 5: ...5 ...

Page 6: ...8 gasket included for ceiling installation Fig 9 screw fan to wall Figs 10 ll make electrical connection using cable clamp Figs A Wiring diagrams follow NB this fan is double insulated and does not need to be earthed N B This fan is NOT suitable for use with a Gravity Grille It should be installed using either a Cowl or Fixed Grille Fig 12 Replace front cover ES1003 JUMPER SWITCH 230v models The E...

Page 7: ...003CF 3 Speed with Filter Cord removed ES100H2C Humidity Control Cord removed 7 WIRING DIAGRAMS VIA REMOTE ILLUMINATED SWITCH ES1003 3 Speed with Cord removed ES1003CF 3 Speed with Filter Cord removed ES100H2C Humidity Control Cord removed N B When installing fans via a remote switch pullcord switch must be left in off position and the cord removed ...

Page 8: ...ed in Zones 1 or 2 but should be installed as close as possible to the fan within Zone 3 The cable used to connect the transformer to the fan must be Class II with a section area of at least 1 5mm2 and a maximum length of 10m If the fan is a humidity control model it must be installed using the transformer supplied for that product The ES1003 fans are designed to run con tinuously at one of 2 lowe...

Page 9: ...n the relative humidity reaches the pre set level and will continue to operate at this speed until the humidity has been dispersed The user can use the cord to operate the fan at its higher speed or to boost the fan speed if it is already running Pulling the cord again will revert the fan to its lower speed and it will continue to run either until the humidity has been removed or the fan has compl...

Page 10: ...s Fig 14 The humidistat can be adjusted Fig 15 between 40 and 90 relative humidity Turn clockwise to decrease sensitivity and set at a higher level of relative humidity The timer is adjustable between 3 and 25 min utes Turn the trimmer Fig 16 clockwise to increase the overrun time or anti clockwise to decrease it ADJUSTMENT OF TRIMMERS ...

Page 11: ...fied technician before reassembling the fan NOTE The motor does not require lubrication as it is maintenance free sealed for life type DISMANTLING RECYCLING This product has been designed and constructed using high quality materials and components that can be recycled or re used Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494...