background image

5

Summary of Contents for eSmile

Page 1: ...continuous running with or without filter humidity control SELV low voltage 3 speed continuous running humidity control for all domestic wet rooms for walls or ceilings IPX4 IPX7 쓑 The Carbon Friendly Fan Installation and Operating Instructions ...

Page 2: ...ct before doing this Do not leave packing material within the reach of children or unskilled people To dispose of the packaging and the appliance at the end of its useful life refer to the recycling norms in force The use of any electrical product requires compliance with some basic rules which are listed below do not touch it with wet or damp parts of the body e g hands feet this appliance can be...

Page 3: ...replacement to ensure maxi mum effectiveness If the product is sited in a room containing a fuel burning appliance which is not of the bal anced flue type the installer must ensure that air replacement is adequate both for the fan and the fuel burning appliance The product must not be used as an activator for water heaters stoves etc The product must not exhaust into ducts designed to evacuate fum...

Page 4: ...ws the fan to run at low speed for its over run period The humidistat is adjustable from 40 to 90 relatve humidity ES1003CLV 12v SELV version of ES1003 ES100H2CLV 12v SELV version of ES100H2C 4 INSTALLATION ...

Page 5: ...5 ...

Page 6: ...8 gasket included for ceiling installation Fig 9 screw fan to wall Figs 10 ll make electrical connection using cable clamp Figs A Wiring diagrams follow NB this fan is double insulated and does not need to be earthed N B This fan is NOT suitable for use with a Gravity Grille It should be installed using either a Cowl or Fixed Grille Fig 12 Replace front cover ES1003 JUMPER SWITCH 230v models The E...

Page 7: ...003CF 3 Speed with Filter Cord removed ES100H2C Humidity Control Cord removed 7 WIRING DIAGRAMS VIA REMOTE ILLUMINATED SWITCH ES1003 3 Speed with Cord removed ES1003CF 3 Speed with Filter Cord removed ES100H2C Humidity Control Cord removed N B When installing fans via a remote switch pullcord switch must be left in off position and the cord removed ...

Page 8: ...ed in Zones 1 or 2 but should be installed as close as possible to the fan within Zone 3 The cable used to connect the transformer to the fan must be Class II with a section area of at least 1 5mm2 and a maximum length of 10m If the fan is a humidity control model it must be installed using the transformer supplied for that product The ES1003 fans are designed to run con tinuously at one of 2 lowe...

Page 9: ...n the relative humidity reaches the pre set level and will continue to operate at this speed until the humidity has been dispersed The user can use the cord to operate the fan at its higher speed or to boost the fan speed if it is already running Pulling the cord again will revert the fan to its lower speed and it will continue to run either until the humidity has been removed or the fan has compl...

Page 10: ...s Fig 14 The humidistat can be adjusted Fig 15 between 40 and 90 relative humidity Turn clockwise to decrease sensitivity and set at a higher level of relative humidity The timer is adjustable between 3 and 25 min utes Turn the trimmer Fig 16 clockwise to increase the overrun time or anti clockwise to decrease it ADJUSTMENT OF TRIMMERS ...

Page 11: ...fied technician before reassembling the fan NOTE The motor does not require lubrication as it is maintenance free sealed for life type DISMANTLING RECYCLING This product has been designed and constructed using high quality materials and components that can be recycled or re used Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494...

Reviews: