background image

Installation
IT IS IMpORTANT THESE INSTRUCTIONS ARE READ FULLY BEFORE INSTALLATION

This product should not be used for any purpose other than that for which it was designed and as shown
in this leaflet.

All packaging should be removed and the unit checked for damage in transit.  If there is any damage, please 
contact your supplier

The EVO90DC will generally be fitted into a loft or ceiling void.  

In order to comply with 

Construction (Design & Management) Regulations, sufficient access for safe maintenance (recommend
ed on an annual basis), or removal following installation, MUST be provided for this product.  See dimen-
sions above.

Fire Dampers 

must be fitted

to duct work at appropriate locations in accordance with Building Regulations

Flue gases from fuel-burning equipment must not be drawn into a living area.  If any room from which air
is  extracted contains a fuel burning appliance, such as a central heating boiler, then its flue must be of 
the sealed or balanced flue type, or allowance must be made for an adequate supply of air into the 
room.

The unit must NOT be installed:
-

where there is excessive oil or grease

-

where there are hazardous gases, liquids or vapours that are flammable or corrosive

-

in ambient temperatures above 50ºC or lower than 5ºC

-

in humidity levels above 90% or in a wet environment

Where possible the unit should NOT be installed directly above a bedroom or living room.  

The condensation drain 

must

be fitted and if insulated, use the equivalent of at least 25mm of insulating 

material with a thermal conductivity of 

0.04

W/(mK)

Care should be taken to ensure that ducting is free from blockages before switching on the unit as this may
invalidate your guarantee

External grilles should be located a minimum of 600mm from any flue outlet in accordance with all
Regulations

The unit must be connected to a 230v-240v, 50Hz single phase electrical supply.  

A triple pole isolation switch with contact  separation of at least 3mm must be used to connect the appliance
to the fixed wiring when using the Switched Live.

The product should only be connected to the mains electricity supply or electrical outlet if:
-  your electrical voltage and frequency correspond to those shown on the rating label.
-  the capacity of your electricity supply is sufficiently powerful to operate the product at its

maximum power.

If one of the spigots is not connected to ducting a safety grille 

MUST 

be fitted to that spigot, so that it is 

impossible for any moving part to be touched.

This appliance is not suitable for installation on the outside of a building

Installation of the appliance 

MUST

be carried out by a qualified and suitably competent person and should be 

carried out in clean, dry conditions where dust and humidity are at minimal levels. 

Page 3

EVO90DC

Reviews: