"MICROBOX" - CONTINUOUS MECHANICAL EXTRACT UNIT

INSTALLATION AND OPERATING INSTRUCTIONS

PLEASE READ THE FOLLOWING INSTRUCTIONS VERY CAREFULLY BEFORE USING THE PRODUCT. THE
MANUFACTURER WILL NOT BE HELD RESPONSIBLE AND DECLINES ANY AND ALL LIABILITY FOR DAMAGE
CAUSED TO PERSONS OR PROPERTY DUE TO IMPROPER USE WITH REFERENCE TO THE PRECAUTIONS
OUTLINED IN THIS MANUAL. 

THIS MANUAL MUST ALWAYS BE READILY AVAILABLE.

MBOX125/2DC:

5"/125mm spigot, for dwellings up to 270m

2

, max capacity 404m

3

/hr

MBOX125/2DC204:

204 x 60mm spigot, for dwellings up to 270m

2

, max capacity 404m

3

/hr

ATTENTION : This symbol indicates that care must be taken in installing this product in order to
avoid (potentially lethal) injury both to installer and user.  This instruction MUST be followed for
installation.

1.

Do not use this product for any purpose other than that for which it was designed and as shown in this leaflet.

2.

Remove all packaging and check that your fan has not been damaged in transit.  If in doubt, contact your 
supplier.

3.

Do not leave packaging within the reach of children or unskilled people. Dispose of hazardous waste (poly
styrene, plastic, polypropylene, etc.) responsibly.

4.

If the product is dropped or badly knocked, contact your supplier, dealer or manufacturer to ensure that it is 
operating properly.

5.

Using any electrical equipment requires compliance with basic safety rules: 

the product must not come into contact with liquid of any sort and should not be touched with wet or 
damp parts of athe body (eg hands, feet)

the product must not be operated by children or other unskilled people.

6.

The product should only be connected to the mains electricity supply or electrical outlet if:

your electrical voltage and frequency correspond to those shown on the rating label.

the capacity of your electricity supply is sufficiently powerful to operate the product at its maximum power

If this is not the case, contact professionally qualified personnel.

7.

Before carrying out any maintenance or cleaning operation, the product must be switched off and disconnect
ed from the main power supply..

8.  If a fault, malfunction or anomaly of any type occurs, the product should be made inoperative (by turning off 

the switch and by disconnecting it from the mains electricity supply) and qualified personnel contacted imme
diately.  Always request original spare parts to carry out any repairs.

9.  If the product needs to be removed, turn off the main network circuit-breaker and then disconnect the appli

ance from that network.

10. The unit should be installed in a safe location as far away as possible from children and/or  unskilled people.

11. The electricity system to which the product is connected must comply with the current standards.

12. In order to comply with Construction (Design & Management) Regulations, sufficient access for safe 

maintenance or removal following installation, MUST be provided for this product.

WARNING : This symbol indicates that care must be taken to avoid damaging your product
when following these instructions

1.

This product is professionally manufactured and complies with the current standards regarding electrical 
equipment

2.

This product conforms with the EEC directive EMC 89/336 concerning the suppression of radio interference 
and electromagnetic compatibility.

3.

This product must not be used in an ambient temperature greater than 40 °C (104 °F).

4.

Do not leave the product exposed to the weather (rain, sun, snow, etc.).

5.  Do not place the unit or any part of it in water or liquids.

6.

When cleaning or performing routine maintenance, check the condition of the appliance.

7.  To avoid the risk of fire, do not use the product in the presence of inflammable substances or vapours such 

as alcohol, insecticides, gasoline, etc.

8.  The air or fumes being extracted must be clean and free from greasy particles, soot, chemicals and 

corrosive agents, inflammable or explosive mixes (if these substances are present, conctact Vectaire  for 
information on more suitable products).

9.

The unit must be installed by professionally qualified personnel.

Summary of Contents for MBOX 125/2DC

Page 1: ...oms whilst allowing the user to boost to maximum performance when required The MBOX125 2DC is generally installed in the loft or roof void and requires only one discharge grille The noise level and ru...

Page 2: ...fire dampers air valves ducting outside grilles and wall cowls SPECIFICATION compact ultra low profile unit casing manufactured from steel lined with acoustic material low energy DC external rotor mot...

Page 3: ...Yes Kitchen 4 additional wet rooms 50 0 65 No Figures from BRE test results at minimum flow rate conditions RESULTS for Approved Document F Exhaust Terminal Configura tion Fan Speed Setting Total Flow...

Page 4: ...AC 10V DC 579 112 2 59 8V DC 404 98 3 47 6V DC 222 68 9 25 8 4V DC 95 43 9 10 2 2V DC 24 23 1 4 2 600 500 400 300 200 100 0 Pressure Pa 0 25 50 75 100 llitres second Dimensions mm Slimline whole hous...

Page 5: ...icrobox DC Models MBOX 125 2DC MBOX 125 2DC204 Continuous Mechanical Extract Ventilation Unit with Low Energy DC Motor for domestic and commercial use Installation Operating and Maintenance Instructio...

Page 6: ...onally qualified personnel 7 Before carrying out any maintenance or cleaning operation the product must be switched off and disconnect ed from the main power supply 8 If a fault malfunction or anomaly...

Page 7: ...exible cord black brown grey and green yellow The unit is suitable for 230V 50Hz Single phase supply fused at 3A A fused spur box or triple pole switch having a minimum contact separation of 3mm must...

Page 8: ...Page 4 DIMENSIONS MBOX125 2DC INSTALLATION DIMENSIONS MBOX125 2DC204...

Page 9: ...Page 5 1 7 6 5 4 3 2 8...

Page 10: ...and COMMISSIONING DIAGRAMS Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494 522337 Email sales vectaire co uk MBOX125 2DC MBOX12...

Reviews: