RESULTS for SAP CALCULATIONS

ENERGY LEVEL PERFORMANCE - using rigid ducting only

Exhaust Terminal Configuration

Fan Speed Setting

Specific Fan Power

(W/l/s)

EST Best Practice 

Performance Compliant

1

additional wet room

100% variable

0.20

Yes

2

additional wet rooms

100% variable

0.26

Yes

3

additional wet rooms

100% variable

0.34

Yes

4

additional wet rooms

100% variable

0.44

Yes

5

additional wet rooms

100% variable

0.55

Yes

Figures from BRE test results at minimum flow rate conditions

RESULTS for Approved Document F

Exhaust Terminal 
Configuration

Fan Speed Setting

Total 

Flow Rate

(l/sec)

Total Flow Rate

(wind condition)

(l/sec)

% reduction of

Total Flow Rate

1

additional wet

room

100% variable

21.0

19.3

8

2

additional wet

rooms

100% variable

29.0

27.9

4

3

additional wet

rooms

100% variable

37.0

36.3

2

4

additional wet

rooms

100% variable

45.0

44.2

2

5

additional wet

rooms

100% variable

53.0

52.5

1

Figures from BRE test results 

Slimline, whole house, mechanical extract ventilation - MEV

Microbox 125/2DC

-B

Technical Characteristics - SAP Results

Page 22

Summary of Contents for Microbox 125/2DC-B

Page 1: ...oms whilst allowing the user to boost to maximum performance when required The MBOX125 2DC B is generally installed in the loft or roof void and requires only one discharge grille The noise level and...

Page 2: ...ire dampers air valves ducting outside grilles and wall cowls SPECIFICATION compact ultra low profile unit casing manufactured from steel lined with acoustic material low energy DC external rotor moto...

Page 3: ...additional wet rooms 100 variable 0 55 Yes Figures from BRE test results at minimum flow rate conditions RESULTS for Approved Document F Exhaust Terminal Configuration Fan Speed Setting Total Flow Ra...

Page 4: ...AC 10V DC 579 112 2 59 8V DC 404 98 3 47 6V DC 222 68 9 25 8 4V DC 95 43 9 10 2 2V DC 24 23 1 4 2 600 500 400 300 200 100 0 Pressure Pa 0 25 50 75 100 llitres second Dimensions mm Slimline whole house...

Page 5: ...robox DC Models MBOX 125 2DC B MBOX 125 2DC204 B Continuous Mechanical Extract Ventilation Unit with Low Energy DC Motor for domestic and commercial use Installation Operating and Maintenance Instruct...

Page 6: ...sionally qualified personnel 7 Before carrying out any maintenance or cleaning operation the product must be switched off and disconnect ed from the main power supply 8 If a fault malfunction or anoma...

Page 7: ...le for 230V 50Hz Single phase supply fused at 3A The unit is supplied with a mains rated 4 core flexible cord black brown grey and green yellow A fused spur box or triple pole switch having a minimum...

Page 8: ...Page 4 DIMENSIONS MBOX125 2DC B INSTALLATION DIMENSIONS MBOX125 2DC204 B...

Page 9: ...Page 5 1 7 6 5 4 3 2 8...

Page 10: ...COMMISSIONING DIAGRAMS Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494 522337 Email sales vectaire co uk MBOX125 2DC B MBOX125...

Reviews: