"WHHR100/60DC" - WHOLE HOUSE HEAT RECOVERY UNITS
INSTALLATION AND OPERATING INSTRUCTIONS

Safety Notice
It is important to read this Instruction Manual carefully before installing or using the product.  Following
these instructions will ensure that your ventilation system is installed, commissioned and used properly and
continues to operate effectively.  Vectaire will not be held responsible and will not accept liability for any
damage caused to persons or property through failure to follow the guidance provided in this manual.   It
should always be available with the product for easy reference.

Your unit SHOULD NOT be switched off. It is designed to run continuously. If it is switched off indoor
pollutant and moisture levels may increase.

WHHR100/60DC:

5"/125mm spigot, for dwellings up to 260m

2

, max capacity 94 l/sec

General Information

The  Vectaire  WHHR100/60DC  heat  recovery  system  provides
whole house mechanical ventilation to living areas,  bedrooms, kitchen
and bathrooms.  They extract stale, contaminated air from kitchens,
utility rooms and bathrooms, and use the heat recovered from this air
to warm fresh, incoming air to create a flow of fresh air throughout
the  dwelling.    The  extract  and  intake  air  streams  are  separated  to
avoid contamination.

Heat is reclaimed from extracted air and used, via the heat exchang-
er, to warm incoming fresh air.  The system will operate continuously
to create a stable, comfortable, healthy environment avoiding the use
of excessive energy and saving heat already generated.

The heat recovery unit will generally be installed in the loft of a house
or the void above the ceiling in an apartment (but may be installed in
a cupboard) and will be connected by hidden ductwork to vents sited
in  the  ceilings  of  the  rooms  which  require  ventilation.    Each  unit  is
commissioned  individually  allowing  its  performance  to  be  tailored  to
suit  the  performance  required.    There  will  be  a  facility  to  boost  the
extraction rate when desired (e.g when cooking or bathing or pollutant levels rise).  This may be done automati-
cally or manually.  

The system is designed to run continuously and should NOT be switched off except for maintenance or filter
replacement.  

Features

SAP Q Eligible

whole house heat recovery units giving continuous ventilation in the kitchen and up to six

additional wet rooms

low noise levels

variable choice low (trickle) speed and boost options for optimum setting at installation

boost speed can be triggered by a switched live connection from a variety of external devices including:
-

PIRFF (passive infra red)

*

-

DRH240 (dynamic remote humidistat)

*

-

THM (thermostat)

*

-

a light switch (if more than one light switch is used, 

each one must be a double pole switch)

-  a remote switch/pull cord 
(

*

PIRFF, DRH240 and THM may have integral over-run timer which controls the length of time that the fan 

will continue to operate at its boost speed after the boost has been switched off.) 

Installation MUST be carried out by suitably qualified personnel and MUST be in accordance with current IEE 
regulations and all appropriate standards and applicable regulatory guidance.