Installation
IT IS IMPORTANT THESE THESE INSTRUCTIONS ARE READ FULLY BEFORE INSTALLATION
•
This product should not be used for any purpose other than that for which it was designed and as shown
in this leaflet.
•
All packaging should be removed and the unit checked for damage in transit. If there is any damage, please
contact your supplier
•
The WHHR 100/60DC will generally be fitted into a loft or ceiling void.
In order to comply with Construction
(Design & Management) Regulations, sufficient access for safe maintenance (recommended on an annu-
al basis), or removal following installation, MUST be provided for this product. See dimensions above.
•
Fire Dampers
must be fitted
to duct work at appropriate locations in accordance with Building Regulations
•
Flue gases from fuel-burning equipment must not be drawn into a living area. If any room from which air
is extracted contains a fuel burning appliance, such as a central heating boiler, then its flue must be of
the sealed or balanced flue type, or allowance must be made for an adequate supply of air into the
room.
•
The unit must NOT be be installed:
-
where there is excessive oil or grease
-
where there are hazardous gases, liquids or vapours that are flammable or corrosive
-
in ambient temperatures above 50ºC or lower than 5ºC
-
in humidity levels above 90% or in a wet environment
•
Where possible the unit should NOT be installed directly above a bedroom or living room.
•
The condensation drain
must
be fitted, and if insulated use the equivalent of at least 25mm of insulating
material with a thermal conductivity of
0.04
W/(mK)
•
Care should be taken to ensure that ducting is free from blockages before switching on the unit as this may
invalidate your guarantee
•
External grilles should be located a minimum of 600mm from any flue outlet in accordance with all
Regulations
•
The unit must be connected to a 230v, 50Hz single phase electrical supply fused at 3A.
•
A fused spur box, or triple pole switch having a minimum contact separation of 3mm must be used for
isolation.
•
The product should only be connected to the mains electricity supply or electrical outlet if:
- your electrical voltage and frequency correspond to those shown on the rating label.
- the capacity of your electricity supply is sufficiently powerful to operate the product at its
maximum power.
•
If one of the spigots is not connected to ducting a safety grille
MUST
be fitted to that spigot, so that it is
impossible for any moving part to be touched.
•
This appliance is not suitable for installation on the outside of a building
Installation of the appliance
MUST
be carried out by a qualified and suitably competent person and should be car-
ried out in clean, dry conditions where dust and humidity are at minimal levels. It should only be installed after other
building works have been completed and the building in which it is installed cleaned. Failure to comply with any of the
above points will have an impact on the validity of the guarantee.
WHHR100/60DC