background image

F

EATURES

•     

SAP Q eligible

(MVHR) residential 

     whole house heat recovery unit for 
     providing continuous ventilation in 
     kitchen and up to 4 additional wet 
     rooms

    maximum airflow 51.3 l/sec

    suitable for areas up to 170m

2

       

92% of heat recovered from stale 

     air extracted from warm, moist 
     rooms replacing it with fresh, 
     filtered, warmed air to create a 
     constant, comfortable, healthy 
     environment

    easy to install and maintain

    for fitting into lofts, voids, false 

     ceilings or cupboards

    variable choice of low (trickle) 

     speed and boost options for 
     optimum setting at installation

    the boost speed can be 

     triggered by a switched live 
     connection from a range of devices:
     -     PIRFF (passive infra red)

*

     -     DRH240 (dynamic remote 

           humidistat)

*

     -     THM (thermostat)

*

     -     a light switch (if more than 
     one light switch is used, 

each 

     one must be a double pole 
     switch)
     

-     a remote switch/pull cord 

     (

*

PIRFF, DRH240 and THM may 

     have integral over-run timer 
     which controls the length of time 
     that the fan will continue to 
     operate at its boost speed after 
     the boost has been switched off.)

    low noise levels

    low running costs

    gives extra security by removing 

     need to open windows

    3 year warranty

    Vectaire Ltd can supply all 

     accessories for use with these 
     units, including air filter cassettes, 
     silencers, fire dampers, air valves, 
     ducting, outside grilles and wall 
     cowls

S

PECIFICATION

•     

compact, low profile unit

•     

casing manufactured from gal-

     vanised sheet with an epoxy finish 

    thermo-acoustic lining in poly-

     propylene to prevent thermal 
     bridging to outside

    low energy DC brushless motor for

     optimum combination of high 
     performance, low noise levels and 
     low energy consumption 

•     

impellers are single width, single 

     inlet, direct drive and forward 
     curved for higher efficiency

    operates in temperatures up to 

     60ºC 

    pre-wired for easy electrical 

     connection

    uses standard, disposable G3

     filters

    counter flow heat exchanger for 

     greater efficiency and increased 
     separation of airflows

Vectaire Ltd offers a design service 
to  ensure that the unit installed is 
the best possible to provide efficient,
effective, low energy and low running
cost ventilation.  Vectaire can also 
organise installation and 
commissioning of these products

Incoming fresh air
Warmed fresh air
Extracted warm, moist, stale air
Cooled outgoing stale air
WHHR100/90DC-B

Tel:  +44(0)1494 522333
Fax:  +44(0)1494 522337

Email:  sales@vectaire.co.uk

Web:  www.vectaire.co.uk  

L

OFT OR

V

OID

I

NSTALLATION

C

OMPLIES WITH

•     

Part L1A and L1B of Building 

     Regulations for enhanced energy 
     saving capability 

    Part F of Building Regulations for

     reliable, efficient ventilation

    manufactured to BS EN ISO 9001

    complies with IEC 60335-2-80, 

     LVD2006/95/CE and EMC 
     2004/108/CE European 
     Directive against radio interference
     and electro-magnetic compatibility

    CE marked

•     

SAP Q eligible

• 

   EST Best Practice 

     Performance Compliant

Whole House Mechanical Ventilation with Heat Recovery - MVHR

WHHR100/90DC-B Plus

Technical Characteristics

Page 5

Summary of Contents for WHHR100/90DC-B Plus

Page 1: ...t provides low level continuous ventilation in a kitchen and up to four wet rooms extracting moist polluted air and replacing it with fresh filtered air recovering up to 92 of the heat from the outgoi...

Page 2: ...manufactured from gal vanised sheet with an epoxy finish thermo acoustic lining in poly propylene to prevent thermal bridging to outside low energy DC brushless motor for optimum combination of high...

Page 3: ...additional wet room 100 variable 0 63 92 Yes Kitchen 2 additional wet rooms 100 variable 0 72 91 Yes Kitchen 3 additional wet rooms 100 variable 0 84 91 Yes Kitchen 4 additional wet rooms 100 variabl...

Page 4: ......

Page 5: ...WHHR100 90DC B Plus Whole House Heat Recovery Unit with Low Energy DC Motor for domestic and commercial use Installation Operating and Maintenance Instructions...

Page 6: ...nt avoiding the use of excessive energy and saving heat already generated The heat recovery unit will generally be installed in the loft of a house or the void above the ceiling in an apartment but ma...

Page 7: ...et environment Where possible the unit should NOT be installed directly above a bedroom or living room The condensation drain mustbe fitted and if insulated use the equivalent of at least 25mm of insu...

Page 8: ...nsate drain is in an unheated space it MUST be insulated with the equivalent of at least 25mm of insulating material with a thermal conductivity of 0 04 W mK The drain must incorporate a U bend to pre...

Page 9: ...the grilles or valves and adjust to suit the design figures by turning the centre of the valve clockwise to decrease the airflow and anticlockwise to increase the airflow If the airflow is still not c...

Page 10: ...Page 6 Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494 522337 Email sales vectaire co uk WHHR100 90DC B Plus Sept2011 E O E...