background image

Page 9 

Summary of Contents for 492EP

Page 1: ...hank you for purchasing this tester The device is exclusively designed for testing the wearing of the wrist strap and footwear Please carefully read this manual before operating the device Store this manual in a safe easily accessible place for future reference ...

Page 2: ...ified specific usag e see test specification The parameters of the tester are set up in th e factory the user can also according to the need to reset 2 Picture 3 Specifications and Characteristics 3 1 Specifications 1 Power supply 9VDC or AC or coupling adapters 8 12VDC 2 Output with nine testing lights sound contact output and lower voltage indicating 3 Contact output Voltage 400V peak value DC A...

Page 3: ...st cables Feet In the three core plug and socket for white Two core shielded wire cable is black including white connecting line for the foot end test black line for shielding grounding line 2 Access control cables Relay Out the plug socket is black Two conductor cable is gray 3 The Power ground wire Power In four core plug socket is white Among them yellow green cables for the grounding line two ...

Page 4: ...column panel comes with three screws nuts will be fixed on the upright post panel Then tester is fixed on the upright post panel floor has three holes on the back of tester pillar panel on the left side of the three screw is used to test instrument are attached in the column on the front panel 8 Access control cables gray and the power supply ground wire gray yellow green can choose according to n...

Page 5: ... wear conditions 3 When dial the code switch 3 in ON said the hand test high end for 35 m Ω When dial the code switch 3 next OFF said the tests of the hand of high end for 10 m Ω Note 750 k wrist low end Ω Once the password after the success need to input the correct password to set the parameters of the acceptable range the maximum and the minimum 8 2 Acceptable range of parameter values set In t...

Page 6: ...f the foot high of 1000MΩ When dial the code switch 4 and 7 are all next OFF said the tests of the foot high of 100M Ω When dial the code switch 7 said in ON ON foot test high end of 35M 5 When dial the code switch 5 in ON said the foot of the tester measuring low at 750KΩ When dial the code switch 5 next OFF and dial the code switch 6 in ON said the tests of the foot low end is 500KΩ When dial th...

Page 7: ...code switch 3 digital dial the code switch 4 5 6 said address 2 Specific shown in the following table In this state the testing value of 492 set the values of the parameters of ep PC software Set up in 492 ep software which can be reference to three qualified range of parameter values set 2 Connection click on the 492 ep PC software has query tester can inquire online communication tester address ...

Page 8: ...whether the connection is good the corresponding wrist band or foot ring conductive shoes anti static shoes are in good condition 6 Battery replacement Body comprehensive test instrument includes a low voltage indicator alarm circuit in the red light please stop test and REPLACE the BATTERY If you don t replace the battery continue to test the test results of accuracy is not guaranteed Battery rep...

Page 9: ...t 2 If need to be connected to the entrance guard system the entrance guard system and will contact switch line connection 5 4 1 Separate Test Separate test state can test the wrist band or foot ring conductive shoes anti static shoes wear conditions 1 Wrist band wear test 1 Wear a good WRIST band the WRIST band cable directly into the WRIST with jack WRIST CORD or connected to a connection column...

Page 10: ...Page 9 ...

Reviews: