4
Precision: Wrist strap’s resistance
±
10%
Footwear’s resistance
±
10%
5
Weight:
0.6kg
6
Out size:
160mm×100mm×40mm
3.2 Characteristics
1. This tester can not only separate test wrist band, one foot or both feet (foot ring, conductive
shoes, anti-static shoes) wear;And set up a comprehensive test mode, can test the wrist belt and at
the same time the foot ring, conductive shoes, anti-static shoes wear situation, save the test time.
2.Tester can be connected to the entrance guard system, the output test
signal to the entrance guard system, control personnel in and out of the need to be protected
against static electricity
3. Tester adopts micro electric current test, make the test more stable, more accurate test data.
4. Tester batteries electricity shortage, low voltage alarm (REPLACE ') in the red light.
4. Installation and connection
1.
The foot end test cables (Feet) In the three core plug and socket for white;Two core shielded
wire cable is black (including white connecting line for the foot end test, black line for
shielding grounding line)
2.
Access control cables (Relay Out) the plug & socket is black;Two conductor cable is gray.
3.
The Power/ground wire (Power) In four core plug & socket is white.Among them,
yellow-green cables for the grounding line, two core gray line for power supply cable (white
line is positive, the black wire is negative).
4.
The telecommunications cable (RS232) plug & socket for four core is black.Among them,
the green line (COM) is a public side, the red line (RXD) for receiving signal, the blue line
(TXD) signal lines for launch
.
5.
The foot end test connection: from the packing column, the foot end test cable wear out
from the post.Pillar top wear out test cables (three core white plug) and tester (three core
white) socket on the back of the line is linked together, at the bottom of the column in the
cable and the cable according to the corresponding plug from the bottom.
Page 2