background image

2.Product Instruction and Parts 

Product instruction 

 

 

 

 

 

2  The  meter  cannot  run  when  the  voltage  is  lower.  And  in  the 

testing  process,  the  meter  sounds  firstly  and  turns  off 

automatically. At the moment, it must replace a new battery. 

3  Replace  a  new  battery:  move  the  lid  and  take  out  the  valid 

battery. And then replace a new battery (refer to the picture). 

 

 

 

 

Note:  *  The  meter  can  work  about  12  hours  continually 

when  using a  new battery.  And  please turn off  the 

power supply when not using. 

* Do not replace the new battery in the testing process 

for protecting the meter from being damage.

 

 

4

3

2

1

P O W

E R

E L E

C T R

O S T

A T I

C   F

I E L

D M E

T E R

1

LCD                                      6

calibrating hole 

2

POWER key                        7

grounding jack to the meter 

3

ZERO key                            8

notch of testing ion balance   

4

STATIC/IB key                    9

ion balance testing plate 

5

HOLD/MAX key                  10

grounding line

 

 

 

 

Page15 

Page2 

Summary of Contents for 496

Page 1: ...TIC FIELDMETER OPERATION MANUAL Thank you for purchasing our electrostatic field meter Please carefully read this manual before operating the system Store this manual in a safe easily accessible place...

Page 2: ...eplacing the fittings Please turn off the power supply when finishing using and take out the battery when not using in a period of time 1 Summary This electrostatic field meter is a special meter for...

Page 3: ...place a new battery refer to the picture Note The meter can work about 12 hours continually when using a new battery And please turn off the power supply when not using Do not replace the new battery...

Page 4: ...e ion balance testing board when testing or else the voltage in the front testing board will be eliminated 5 Replace the battery 1 means the voltage is full means the voltage is enough means the volta...

Page 5: ...range low 0 1 50KV high 1 22 0KV Auto switch between low and high ion balance testing range 0 220V measure distance static 25mm 0 5mm 1 Insert the ion balance testing plate to the notch refer to the...

Page 6: ...6 Ion Balance Testing Instructions P O W E R E L E C T R O S T A T IC M E T E R th e n o tch th e fro n t testin g p late th e b ack testin g p late in sert th e io n b alan ce testin g p late to th e...

Page 7: ...working until displaying OFF th e tested o b ject g rap h em ic g ro u n d in g 2 5 m m E L E C T R O S T A T I C F I E L D M E T E R P O W E R 1 Press power key to select the working mode and then g...

Page 8: ...t it into the grounding hole of the meter The surface is ESD and it is Ground of the meter 2 Conductor the resistance of the meter is high and the body water wet some things earth and some wall are co...

Page 9: ...g plate to the Ground of the meter Press ZERO key about two seconds to zero After un pressing the key the meter sounds and displays 0 if zeroing successfully 4 3 switch between the static testing and...

Reviews: