23
Origin BTN
Input the reset signal into the unit by corresponding signal pin, and the
unit will run the reset (ORG) operation.
Stop BTN
Input the stop signal into the unit by corresponding signal pin, and the
unit stops the current operation.
Start BTN
Input the start signal into the unit by corresponding signal pin, and the
unit starts to work or pauses the current work.
Foot BTN
Input the foot switch signal into the unit by corresponding signal pin and
the unit runs the foot switch operation and the function is similar with the
“Start BTN”.
Safe flag-1
Input the signal “breakover ground” into the unit by corresponding signal
pin and the unit comes into the testing state (cannot move and can only
be programmed).
Safe flag-2
Input the signal “break over ground” into the unit by corresponding
signal pin and the unit comes into the testing state (cannot move and can
only be programmed).
Lack fault
Input the signal “lack fault” into the unit by corresponding signal pin and
the unit comes into the process, such as stop working, alarming etc..
Block fault
Input the signal “block fault” into the unit by corresponding signal pin
and the unit comes into the process, such as stop working, alarming etc..
Temp fault
Input the signal “temp fault” into the unit by corresponding signal pin
and the unit comes into the process, such as stop working, alarming etc..
Temp/Feed fault
Input the signal “temp/feed fault” into the unit by corresponding signal
pin and the unit comes into the process, such as stop working, alarming
etc..
Upper CS
Input the signal “cylinder up sensor (in retraction state)” into the unit by
corresponding signal pin and the unit judges the position of cylinder
whether in retraction state.
Nether CS
Input the signal “cylinder down sensor (in reaching state)” into the unit
by corresponding signal pin and the unit judges the position of cylinder
whether in reaching state.