Fill the chemical tank 

 

 

Pour the special fogging chemical mixture into the chemical tank. It is important not to add more chemical than it’s 
needed. Once you have used the machine, please make sure there is no chemical left in the tank. Chemicals can 
solidify and could block the system next time round. When you finish filling the tank, close the tank cap tightly. 
 

                                                

             

 

To turn on the machine

 

 

Press the power button “START” and keep it pressed for 8 to 10 seconds once you hear combustion starting (sounds 
like small explosions). After the engine starts, leave the machine to warm up for around 10 to 20 seconds before 
opening the chemical valves.  
 

 
 

                                 

                                         

       

 

 
 

TIP: If the machine fails to start, press the STOP button (air release) so pressure can be re-established. Press and hold 
the start button again for 10 seconds until it starts. If it fails to start, repeat the procedure. 

 

 

 

                              

                                          

 

 

 
 

Chemical  

START 

HOLD 

10 MIN

 

HOLD 

10 MIN

 

STOP 

Summary of Contents for VECTORFOG H400

Page 1: ...isk of fire CAUTION MARKS Please read this manual before using the equipment You must wear protective equipment face breathing mask protective clothing gloves etc when handling potentially hazardous c...

Page 2: ...Fuel Petrol Fuel Consumption 1 8 Litres Per Hour Start Automatic Fuel Tank Capacity 3 8 Litres Performance 23kW 30 08 hp Weight net 36 Kg Dimensions 162 x 110 x 58 cm Additional Features Tool Kit Clea...

Page 3: ...r are all housed inside of the main body of the machine Operating at its optimum performance combustion and injection is repeated with a frequency of around 200 250 cycles per second Once the machine...

Page 4: ...power supply is being used 110 220 volts Connect the charger to the unit and then connect to the mains When first purchased the machine requires around 8 to 10 hours to fully charge Fill the fuel tan...

Page 5: ...ank cap tightly To turn on the machine Press the power button START and keep it pressed for 8 to 10 seconds once you hear combustion starting sounds like small explosions After the engine starts leave...

Page 6: ...the Chemical Supply Valve clockwise to stop the supply of chemical to the resonator Before turning the Close Valve off keep it running for 5 10 seconds to get rid off any chemical mixture still in th...

Page 7: ...spark plug using a spanner or spark plug remover Remove any carbon deposits between the electrode and the earth section with a wire brush Make sure that there is a space of 3 5 mm between the electrod...

Page 8: ...embled The distance between the petal valve and the valve plate o should be approximately 1 mm COMMON TROUBLESHOOTING If there is no ignition If there is noise coming from the engine but there is no i...

Page 9: ...sure the seal in the petrol cap is not damaged Make sure the cap is firmly closed to prevent leakage Unscrew the fuel injector and examine that the injector hole is not blocked If blocked clean with...

Page 10: ...ng compressed air to remove any blockages Check there is no leaks in the chemical tank Blow compressed air backwards though the chemical tube from the inlet nozzle to see if any bubbles appear Replace...

Page 11: ...0 Engine 11 Ejection nozzle 12 Nozzle 13 Ring 14 Nut 15 Engine upper pipe 16 Plug 17 Plug cap 18 Metal grip 19 O ring 20 Engine rear peg 21 Reducer 22 Run tee 23 Elbow 24 Explosion pipe 25 Air gasket...