background image

1

IMPORTANT SAFETY INFORMATION

Be sure to read and understand all WARNINGS and CAUTIONS before using this

product. Please read this guide carefully before use to ensure optimum performance

and avoid damage to the system or items that you are using it with. Failure to follow

instructions may cause property damage, and/or personal injury. Warnings define

conditions that can cause injury to people. Cautions define conditions that may cause

damage to equipment.

WARNINGS:

1.   Improperly attached hoses or nozzles can fly out under compressor pressure.

Make sure all connections are tight before turning compressor ON.

2.   There is risk of dust or dirt projectiles being released if the compressor hose or

nozzles are not clean when the compressor is turned on.

3.   Wearing protective goggles while operating these appliances can protect eyes from

flying particles of dust and dirt.

4.   Keep out of reach of children. These appliances are not toys!

5.   Replace worn or defective parts immediately - contact Vector

®

customer 

service department at (954)584-4446 or toll free at 866-584-5504.

6.   During AC recharge, make sure that the AC charging adapter is kept away from

water or moisture during use. If recharging around water, make sure the 110 volt

AC outlet is GFCI protected.

7.   Make sure all cords and adapter wires are placed so they are not tripped over or

damaged by pinching, abrading or cutting. Do not place wires near moving

objects, doors or sharp objects.

8.   Never exceed recommended pressures - bursting articles can cause serious injury.

Always check pressure with the pressure gauge.

9.   Do not carry charger and adapters by their cords; carry items by the body of unit

itself.

10. There are no user serviceable parts except for replaceable battery pack, AC

recharge adapter, and hose. 

11. Do not operate unit if there is any evidence of damage.

12. Never use air compressor or inflator near flammable liquids, gas or open flames.

13. Keep working area well lit.

14. Do not direct air into eyes, ears, nose or other parts of the body.

CAUTIONS:

1.   When the compressor or lamp are powered from external DC, make sure the 

voltage is rated at 12 volt DC. Do not operate with 6 volts or 24 volts.

2.   Make sure that the appliances are not operated continuously for more than 

10 minutes. Allow to cool for at least five minutes before turning back on.

3.   Make sure battery pack is fully charged before operating. Recharge every 60

days for the recommended time to extend life of battery pack’s internal battery.

For immediate use, attach the DC adapter and operate the appliances from an

external 12 volt DC source.

4.   To avoid over-inflation, carefully follow instructions on articles to be inflated.

5.   Never leave appliances unattended while in use. Allow compressor to cool for five

minutes after 10 minutes of continuous operation.

6.   Do not use accessories that are not designed to be used with these appliances.

7.   Do not place battery pack on heater; and keep it out of sunlight.

8.   Do not charge battery when it is at or above 122° F (50° C). Allow the battery

pack to cool before charging.

2

CONTENTS

1.  Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 

2. Additional key features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3. Attaching the compressor’s air hose  . . . . . . . . . . . . . . . . . . . . . 5

4. Powering the compressor or lamp . . . . . . . . . . . . . . . . . . . . . . . 5

4.1 Powering from the battery pack  . . . . . . . . . . . . . . . . . . . . 5

4.2 DC power adapter use  . . . . . . . . . . . . . . . . . . . . . . . . 5, 6

5. Charging/recharging the battery pack  . . . . . . . . . . . . . . . . . . . 6

5.1 AC Recharge of battery pack . . . . . . . . . . . . . . . . . . . . 6, 7

6. Compressor/tire inflator  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

6.1 Tire inflation or products with a valve stem  . . . . . . . . . . 7, 8

6.2 Inflate other articles (without valve stem)  . . . . . . . . . . . . . . 8

7. Typical inflation times  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

8. Lantern light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

8.1 Parts replacement lantern light  . . . . . . . . . . . . . . . . . . . . 10

8.2 Quartz halogen bulb replacement  . . . . . . . . . . . . . . 10, 11

8.3 Fluorescent lamp replacement  . . . . . . . . . . . . . . . . . . . . 11

9. Maintenance/replacement parts  . . . . . . . . . . . . . . . . . . . . . . .11

10. Battery replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11

11. Battery disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

12. Specifications  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

Warranties  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

VEC258 Manual 3/03.qxp  1/23/07  5:18 PM  Page 1

Summary of Contents for AIRPRO VEC258

Page 1: ... all returned items after 30 days During the warranty period Vector Manufacturing Ltd will be responsible for the return shipping charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our se...

Page 2: ...if there is any evidence of damage 12 Never use air compressor or inflator near flammable liquids gas or open flames 13 Keep working area well lit 14 Do not direct air into eyes ears nose or other parts of the body CAUTIONS 1 When the compressor or lamp are powered from external DC make sure the voltage is rated at 12 volt DC Do not operate with 6 volts or 24 volts 2 Make sure that the appliances ...

Page 3: ...antern Light Combo This system is an advanced high pressure up to 260 PSI multi use air compressor system with unique features that set it far above the value and util ity of ordinary compressors for mobile use It is supplied with a standard tire valve chuck for filling auto truck bike and motorcycle tires Additionally two different adapters are supplied to inflate soccer balls footballs and popul...

Page 4: ... S AIR HOSE The air hose is supplied as a separate item from the compressor body The hose has a ribbed brass fitting at one end and a standard tire chuck at the other end To use the hose it must first be connected to the compressor outlet Loosen the hose retaining ring counterclockwise insert the hose fitting into the short rubber sealing sleeve Make sure the hose fitting is inserted fully into th...

Page 5: ... 235 85R 16 50 psi 16 00 min BICYCLE TIRES TIRE SIZE PRESSURE TIME FROM 0 PRESSURE 27 x 1 racing 10 psi 40 sec INFLATABLE ARTICLES ITEMS PRESSURE TIME FROM 0 PRESSURE Football 13 psi 24 seconds Basketball 9 psi 20 seconds Volleyball 5 psi 6 seconds 7 FIGURE 4 To remove the battery pack from the appliance body for charging make sure the trigger switch is OFF Press both battery pack release buttons ...

Page 6: ...s touched clean the bulb with alcohol on a clean cloth after the bulb is installed 9 8 LANTERN LIGHT The lantern light comprises three lights in one The spotlight provides a bright focused light A bright long lasting fluorescent lamp provides general area lighting A three position slide switch turns the fluorescent light on and off This switch also turns a three LED emergency flasher on and off Th...

Page 7: ...kwise the small screw at the top of the lens 2 Slide the lens down from the top of the unit The lens will come off Set the lens aside 3 Remove the fluorescent tube by turning one quarter turn so pins at both ends of the tube are released from the sockets The tube will come out 4 Set the defective tube aside for proper disposal 5 Put in a new tube being careful to keep the bulb pins from bending 6 ...

Reviews: