background image

3

4. Charge until the green Recharge LED flashes, then goes from lit to unlit, indicating

the battery is fully charged.

Battery charging times will vary depending on whether the unit is in the OFF or Low

brightness setting and the discharge status of the battery. Monitor the green

Recharge LED. In the OFF setting, allow at least 10 hours for complete recharging,if

battery is discharged.

Battery Replacement

The rechargeable battery is contained in the base of the lamp. It should be replaced

when it will no longer hold a charge.

Before replacing the battery, disconnect the 120 volt AC/DC Power

Adapter/Charger from the AC outlet.

You will need a 6 volt, 6 amp/hour

replacement battery (Vector part# VEC199) and a small Phillips screwdriver. The

procedure to replace the battery is as follows:

1. Set the lamp on its side.
2. Peel back the rubber pad on the bottom of the lamp base and remove the four

screws located there.

3. Separate the base bottom from the top.
4. Observe the RED wire and BLACK wire battery connections.
5. Lift the battery away from the base and circuits.
6. Remove the slide-off connectors from the battery tab connectors. (Note that the

tabs are different sizes to avoid confusion.)

7. Dispose of the disconnected battery properly.
8. Place the RED and BLACK wire connectors on the new battery, making sure the

RED wire connector is on the POS (+) terminal and the BLACK wire connector is

on the NEG (–) terminal.

9. Check lamp for operation by pressing the Brightness Selector.

10. Place the battery in the base and reassemble the base.
11. Replace the four screws — DO NOT OVERTIGHTEN. Press the rubber pad back

in position. 

12. Charge the new battery as instructed above.

Battery Disposal

Non-Spillable Sealed Lead Acid Battery: This battery is fully recyclable and should

be accepted at any location that accepts common automotive starter batteries. 

Examples of places that accept these batteries are: county or

municipal recycling drop-off centers, scrap metal dealers and

retailers who sell automotive replacement lead acid starter

batteries. For more information on recycling this battery, call

toll-free (877) 288-7722.

WARNINGS

• Do not dispose of the battery in fire or expose the battery to fire or

intense heat. This may result in an explosion.

• Before disposing of the battery, protect exposed terminals with

heavy-duty electrical tape to prevent shorting, which can result in

injury or fire.

Bulb Replacement

The supplied 10 watt quartz halogen lamp is a projection quality bulb. Operating

the lamp at full brightness for long periods reduces the bulb's life.

CONTAINS SEALED,

NON-SPILLABLE BATTERY

2

Using the 120 Volt AC/DC Power Adapter/Charger 

to Power the Lamp

• Plug the 120 Volt AC/DC power adapter/charger’s barrel connector into the

Recharge Port located on the base of the lamp (see below).

• Plug the AC/DC power adapter/charger’s plug into a powered 120 volt AC wall

outlet.

Make sure that the AC charger/adapter is powered from the correct AC source. It

must only be powered from 110 volts AC 60 Hz. The AC charger/adapter is rated

for indoor use and must be kept dry. Only use the supplied AC charger/adapter

with this lamp. Substituting this AC charger/adapter for another may damage the

lamp's internal charging circuits and void the warranty.

OPERATING INSTRUCTIONS

The lamp is controlled by the Brightness Selector pushbutton (see page 2). Pressing

the selector once turns the lamp on at a High brightness; pushing it again sets the

brightness to Low. Pushing it a third time turns the lamp OFF.

CARE AND MAINTENANCE

Cleaning

Over time, dust or fingerprints may accumulate on the lamp. If necessary, clean the

lamp with a soft, clean, oil-free cloth moistened with window cleaner. Do not 

use alcohol-based cleaners on the plastic surfaces, as this will eventually cause

surface clouding. If the inside of the plastic guard becomes dirty, disassemble as

you would for bulb replacement (see page 4) and clean with window cleaner.

Battery Care

There is a direct trade-off between lamp brightness and battery charge duration.

The lamp will operate longer in the Low brightness setting.
Operating your lamp while it is connected to a 120 volt AC power source through

the supplied AC/DC Power Adapter/Charger does not expend battery power. Your

lamp battery cannot be overcharged if left continuously connected to the

charger/adapter. 

Battery Recharging

The lamp should be recharged after each use (or every 60 days, if not used) or if

the battery becomes discharged. When the lamp becomes dim when the Brightness

Selector is set to High, the battery has become discharged.
To recharge the battery:

1. Make  certain the lamp is in the OFF or Low brightness setting. The lamp cannot

be recharged in the High brightness setting.

2. Connect the 120 volt AC/DC Power Adapter/Charger as described in the

“Powering the Lamp” section on page 2 (where you will also find other

powering/charging directions and recommendations).

3. The green Recharging LED will light to indicate the battery is charging.