Alarms
There is an alarm banner (919) at the bottom of most screen pages.
When the cause of the alarm is cleared, in most instances it is required that the RESET
button (974) is pressed to remove the screen alarm message.
Common operation alarms able to resolved by operators are:
Alarm
Cause
Remedy
Emergency Stop
E Stop Circuit broken
Reset E stop and/or pullwire
General set required
Home machine
Press Gen Set (functions page)
Vac fail in cycle
Vac status low in cycle
Check vacuum pods for leaks
Air Pressure Low
Supply air press low.
Check supply air
Safety hood not closed
Hood open
Close hood
Board sensor during z up Head too close to panel Drive clear of panel then z lift
on Z lift
Tape not cut
End trim cut not complete Check end trim cutter and travel.
CW limit reached
C Axis over limit
Re-position panel
CCW limit reached
C Axis neg overlimit
Re-position panel
Setpoint outside range
Start position set issue
Re-set start position within limits
Glue temp low
Glue heating
Auto reset
Load new glue cartridge
Glue cartridge low
Load new glue cartridge
Clear tape
Tape in guide
Remove tape from present switch
Z Axis not down
Z not completely down
Remove obstruction
A more comprehensive alarms list is found in section 11 Troubleshooting