5.3.3 Testing End-Limit Switches
It is important to check that the end limit switches are working properly. This should
be done before checking the counters, as the X negative limit switch is also the X
Axis zero reset for the counter.
To test the inputs for the end limit switches, go to the control screen and press the
troubleshooting button (16)
When in the troubleshooting page it is now possible to access the wiring diagrams
and inputs and outputs pages using the Wiring Diagram icon (17)
Throughout the wiring diagram and in/out pages, the relevant inputs and outputs are
illuminated RED when on and Grey when off.
The image on the next page shows the firs page of the wiring diagrams which
displays all of the machine inputs. The X Axis limit switches are displayed in
positions (18) and (19).
16
17