Assembly
5
________________________________________________________________________________________
_______________________________________
5
-
17
Now move the machine back until it almost (but doesn’t quite touch the zero switch)
and then move all the way back to the right position. Check the number again to
ensure no counts have been lost.
Note it is important not to touch the zero switch as otherwise it will re-zero (even if
counts have been lost). If counts are being lost, watch the LED’s on the counters
while slowly moving the head to ensure 20 counts are being made on each tooth and
that a good positive quadrature signal is being achieved (it should be a reasonably
even spacing between each state change of a proximtiy).
Perform the same test for both X and Y axes.
5.4
Preparations for no-load tests without workpieces
After assembly, check the following:
5.4.1 Mechanical
Check all visible screw connections for firm seating.
Close the protective hoods.
Attach the necessary protective devices. Clear the machine of any extraneous
material (wood, forgotten tools etc.).
5.4.2 Electrical work (provided by others)
Check that the electrical work has been performed correctly in accordance with the
customer’s and local regulations.
Check and adjust the protective devices
This includes the air pressure switch (30) and emergency stop pullwire
DANGER !
DANGER !
Summary of Contents for Revolution 180