4
8.1.3 Emergency cut-out
•
Control panel emergency switch-off (823) mounted on front door of control cabinet
•
Emergency Pull wire (806) mounted at front right hand corner of the machine with pull wire
extending all the way around the machine.
•
In case of emergency, stop machine by switching off and disconnecting machine at wall
or by pushing the large red emergency-off button (823) or tripping pull wire (806).
•
The red emergency-off button remains locked in the
OFF
position.
•
The emergency pull wire is fail safe against wire breakage and remains off until reset
manually.
•
The machine may only be re-started after releasing the red button lock and clearing the error
messages with the reset button (828)
8.1.4 Power failure
The machine is safety-protected and will not re-start on its own after a power failure (CE only)
8.2
General Reset
Upon startup from power off, when the emergency circuit is reset and all alarms are cleared (refer
8.1), a General Set must be performed. A General Set required message will blink on the screen.
This serves the purpose of setting the zero point for each of the axes X, Y and C and is critical to
the correct functioning of the machine.
Ensure that all axis movements are free from obstruction prior to performing a general set
so as to avoid the possibility of damage.
Access to the General Set screen button is through the Functions Page. From the home screen,
press the Functions Icon (829)
This will take you to the functions page where the General Set Icon is position (819)
CAUTION !