The icon will indicate with a tick when positive
Temperature can be set by touching the bottom of the glue icon (993) which will take you
to the Glue Advanced Controls page.
comb temperature (994) is the
temperature of the comb
element against which the
glue cartridge is pressed.
The Nozzle element (995) is
the nozzle block which
contains the dosing bar.
9.1.3.1
Setting the glue height to match panel thickness
The glue flow is controlled by the dosing cylinder and dosing bar. The dosing cylinder
serves to rotate the dosing bar to align the appropriate slot of the dosing bar to the nozzle
holes.
There are 5 holes around the dosing ring (917) representing each of the set panel
thicknesses (example 16mm, 19mm, 25mm,18mm and 30mm).
These settings will be
specific for each machine as ordered. If different sizes are required, these can be
supplied as requested and simply fitted.
To change this setting, the glue temperature must be above 160
degrees. Otherwise damage can occur.
This frees the dosing bar to be turned. Remove the pin (918) and use this pin to rotate
the dosing ring (917) to align with the chosen panel thickness.
CAUTION !
994
995
997
996
917
918