Run
9
________________________________________________________________________________________
_______________________________________
9
-
22
The tape presser shoe (919) should be released by removing the pin (925) and pushed
back or removed
Ensure the glue is turned on (926)
Make a V-shaped piece of cardboard to pump the glue into. Corrugated box cardboard is
good because if forms a V easily if folded along the corrugations and is firm enough to
support the hot glue.
Now touch Purge Glue (951) which will activate the air cylinder which presses the glue
cartridge and also opens the glue dosing bar (provided appropriate temperature is
reached).
Glue will start to flow.
If the cartridge has not released from it’s teflon infeed tube, the glue flow will be slow.
Leave the dosing bar open and glue pressure on and wait for the cartridge to release.
This will be obvious when the glue starts to flow freely in creamy spaghetti like lines.
If necessary, switch off both pressure and dosing bar and replace the cardboard V with a
fresh piece to check the flow.
DANGER!
Molten glue at approximately 200 degrees C is dangerous. Ensure it does not get
on skin. Wearing of appropriate gloves is recommended when performing this
procedure.
In the event of glue burns, Run under cold water for 10 minutes and seek medical
advice.
Nozzle
face
919
925
920
Summary of Contents for Revolution 180
Page 1: ...Operating Manual...