FIRST AID:

• SKIN: If battery acid comes in contact with skin, rinse immediately with water, then

wash thoroughly with soap and water.  If redness, pain, or irritation occurs, seek

immediate medical attention

• EYES: If battery acid comes in contact with eyes, flush eyes immediately for

a minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION

3.

CHARGING/RECHARGING

For maximum battery life, we recommend the VECTOR

®

 JUMP-STARTER system is kept

fully charged at all time. If the battery is allowed to remain in a discharged state,

battery life will be shortened.

NOTE:

 Recharging battery after each use will prolong battery life; frequent discharges

between recharges will reduce battery life

IMPORTANT:

• MAKE SURE ALL SWITCHES ARE TURNED OFF DURING RECHARGING

• Charge unit for full 24 hours using AC method, prior to first use

• Recharge unit fully after each use

• Recharge unit every two months, when it has not been used

3.1

110/120 VOLT AC CHARGING

1. Simply plug the AC plug of the AC/DC adapter/charger into any standard 110/

120 volt AC wall outlet.

2. Plug the barrel connector attached to the AC/DC adapter into the small barrel

receptacle on the jump-starter that is marked recharge port.

3. Charge this device for at least 14-16 hours or until the green FULL indicator lights.

4. When charging is completed and the FULL light lights, remove the AC/DC charger

plug and store in a safe place.

NOTE:

The unit cannot be overcharged using the AC method. The VECTOR

®

 JUMP-STARTER

system also comes with a DC/DC charging adapter for recharging the unit from a 12

volt DC cigarette lighter or accessory socket in a vehicle or boat .

This recharging method will NOT recharge the unit as effectively as recharging from a

110/120 volt AC outlet. The 12 Volt DC recharging procedure is recommended only

when it is necessary, as continued use of the 12 Volt DC recharging procedure may

shorten the battery system’s life .

If unit is fully discharged, it is recommended that the vehicle being used for recharging

be left running while the unit is being charged via the 12 Volt DC method.

WARNING:

Do not recharge for more than 3-4 hours maximum using 12 Volt DC method

Vec021APC manual 10/02

12/3/02, 10:57 AM

9

Summary of Contents for Start-It VEC021APC

Page 1: ...ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28TH WAY FT LAUDERDALE...

Page 2: ...4 OPERATING AS A PORTABLE POWER SUPPLY 10 5 EMERGENCY WORK LIGHT 10 6 COMPRESSOR TIRE INFLATOR 11 6 1 Warnings for Compressor Use 11 6 2 Tire Inflation or Products w Valve Stem 11 12 6 3 Inflate other...

Page 3: ...g this unit in proximity to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehicle components 10...

Page 4: ...t 5 This system is designed to be used only on vehicles with 12 Volt DC battery systems Do not connect to a 6 Volt or 24 Volt battery system 6 This system is not designed to be used as a replacement f...

Page 5: ...t any engine system with a standard 12 Volt DC battery boat truck car airplane RV personal watercraft snowmobile garden tractor gasoline engine generator etc Operate 12 Volt DC fans inflators fluoresc...

Page 6: ...e 16 Compressor Power Switch ADDITIONAL FEATURES Includes non spillable maintenance free heavy duty new high energy density 19 Amp hour sealed battery Sturdy and unique compact design provides up to 3...

Page 7: ...te hydrogen gas during normal operation More gas is generated when the battery is charging Hydrogen gas is explosive poisonous to breathe and highly flammable Recommendations for optimum performance o...

Page 8: ...ns are made This delay is designed to reduce the possibility of sparking upon connection We recommend waiting one 1 minute after making the clamp connections prior to attempting to start vehicle 6 Sta...

Page 9: ...ger into any standard 110 120 volt AC wall outlet 2 Plug the barrel connector attached to the AC DC adapter into the small barrel receptacle on the jump starter that is marked recharge port 3 Charge t...

Page 10: ...N AS A 12 VOLT PORTABLE POWER SUPPLY 1 Lift up the cover of the unit s 12 Volt DC accessory receptacle See Figure 1 2 Insert the 12 volt DC plug from the appliance into the receptacle on the unit 3 Sw...

Page 11: ...nit controls the power to the compressor and the gauge light Refer to Figures 3 for locations of compressor hose nozzle storage hatch and hose Return hose to the storage compartment after use 6 1 WARN...

Page 12: ...e 5 Turn ON compressor switch inflate to desired pressure or fullness 6 Turn off compressor switch 7 Remove adapter from the inflatiable item 6 4 TYPICAL INFLATION TIMES The following are approximate...

Page 13: ...free non spillable sealed lead acid battery This battery is fully recyclable and should be accepted at any location that accepts common automotive starter batteries Examples of places that accept thes...

Page 14: ...ies bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipp...

Page 15: ...15 Vec021APC manual 10 02 12 3 02 10 57 AM 15...

Page 16: ...16 2002 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA Vec021APC manual 10 02 12 3 02 10 57 AM 16...

Reviews: