background image

h. See operating instructions for length of charge information.

INTRODUCTION AND FEATURES

Thank you for selecting the Vector(r) Model VEC078 2/15/100 Automatic Battery Charger. With proper

care and use, it will give you years of dependable service. Please read all safety warnings and cautions,

and this entire User’s Manual, before using this device. The manual should then be retained for easy refer-

ence whenever the unit is used.
This model battery charger has a high charge rate of up to 15 amps, and low charge rate of up to 2 amps

(12 Volt only). It is intended for charging only 12 volt and 6 volt lead-acid batteries - maintenance-free and

conventional automotive - that are usually used in cars, trucks, farm equipment, boats, RVs and SUVs, lawn

mowers and garden tractors, motorcycles, personal watercraft, snowmobiles, ATVs, and various light com-

mercial applications. This charger can assist in engine starting by delivering up to 100 amps for up to five

seconds.
Charges 12 Volt automotive batteries in only 3-6 hours. A four position rotary Charge Rate Switch controls

output voltage and current. From left (clockwise) to right:

a) Engine Start (to 100 Amps - 7.2 volts only)
b) 12 volt 2 Amp (automatic)
c) 12 Volt 15 Amp (automatic)
d) 6 volt 15 Amp (manual charging)

A two-position Charge/Start Selector slide switch enables the Engine Start function when the Charge Rate

Selection Switch selects Engine Start.
Built-in meter displays charge rate and battery charge level on color-coded, easy-to-read display.
• Automatically taper charges and stops charging when battery is fully charged to 12 volts.
• Manually charges 6 volt battery at up to 15 amperes (will taper but not automatic Off when fully charged).
• Heavy-duty transformer and rectifier for dependability
• Built-in circuit protection guards against short circuit
• Automatically checks for correct polarity (requires a minimum of 4 volts DC at the battery terminals)
• Heavy-duty cables and copper clamps are corrosion-resistant for better connections
• Connect to side- or top-mount battery terminals
• Rugged steel case with baked-on finish, plus sturdy handle
• Ideal for charging or boosting during winter season when the starting performance of vehicle batteries is

lowered by cold or extreme weather conditions. See Figure 2.

FIGURE 2

4

1. AMMETER

2. BATTERY CLAMPS

3. HANDLE

4. CHARGE RATE SWITCH

5. GROUND PLUG

6. CHARGE/START SWITCH

7. 12V FULL

8. REVERSE CONNECTION LED

1

2

8 7

6

5

4

3

Summary of Contents for START-IT VEC078

Page 1: ... rather than cord when disconnecting charger 4 An extension cord should not be used unless absolutely necessary Use of an improper extension cord could result in a risk of fire and electric shock If extension cord must be used make sure a That pins on plug of extension cord are the same number size and shape as those of plug on charger b That extension cord is properly wired and in good electrical...

Page 2: ......

Page 3: ...f your problem is not covered by this warranty call our Technical Support Department at 954 584 4446 or Toll Free 866 584 5504 for general repair information and charges if applicable STATE LAW RIGHTS This warranty gives you specific legal rights Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the e...

Page 4: ... to an average automotive battery For smaller batteries the charge time should be adjusted using the formula shown below and adding 1 hour to the time calculated To estimate charging time for a discharged battery divide the AH rating of the battery by the charge rate selected This is the number of hours required to recharge the battery For example a 50 AH 12 volt battery is discharged to 10 volts ...

Page 5: ...h an electric cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local electric codes and ordinances DANGER NEVER alter an AC cord or plug If the plug will not fit the outlet have a proper outlet installed by a qualified electrician Improper connection can result in a risk of elect...

Page 6: ...8 inches above the floor as stated by the National Electrical Code DC CONNECTION PRECAUTIONS 1 Connect and disconnect DC output clips only after removing AC cord from electric outlet 2 Never allow clips to touch each other 3 Attach clips to battery posts and twist or rock back and forth several times to make a good connection This tends to keep clips from slipping off terminals and helps to reduce...

Page 7: ...zero charge level and that the charger is operating at peak amperage If after 5 minutes charging time the ammeter reading has not decreased unplug the charger and discontinue the charging process Using a voltmeter determine the voltage of the battery and if it is under 12 volts under 6 volts for 6 volt batteries the battery is probably beyond repair or recharging and will need to be replaced If th...

Page 8: ...POS P or red d Stand as far back from battery as possible and do not face battery when making final connection e Carefully connect the Negative BLACK charger clamp to the free end of the battery cable connected to the negative terminal Connect the charger s power cord to a grounded 110 120 volt AC power outlet and refer to section 8 for approximate charging times f When charging is completed disco...

Page 9: ...kwise to right a Engine Start to 100 Amps 7 2 volts only b 12 volt 2 Amp automatic c 12 Volt 15 Amp automatic d 6 volt 15 Amp manual charging A two position Charge Start Selector slide switch enables the Engine Start function when the Charge Rate Selection Switch selects Engine Start Built in meter displays charge rate and battery charge level on color coded easy to read display Automatically tape...

Page 10: ...HT fully clockwise 6 Volt 15 Amp 6 medium and large 6 volt batteries WARNING IF IN DOUBT ABOUT SELECTING A CHARGE RATE SELECT THE LOWER RATE BATTERIES GET WARM DURING CHARGING IF BATTERIES ARE GETTING HOT DISCONTINUE CHARGING AND INVESTIGATE FOR DAMAGED BATTERY The Charge Start Selector switch in the Start position protects the Ammeter from reading excessive current When the Charge position is sel...

Page 11: ...before a battery begins to accept a measurable rate of charge it can be as long as 4 8 hours from the time the charging process begins Pre charge activation is indicated if the ammeter reading is zero and a hydrometer or voltmeter reading shows that the battery is fully discharged NOTE The newer high calcium type 12 Volt DC batteries may need pre charge activation if their charge has been allowed ...