background image

7

TROUBLESHOOTING
ProblemPossible Cause/Remedy

• Travel Cooler/Warmer

is not functioning as cooler or warmer (fan is not turning)

• Accessory outlet of DC power supply is not functioning -check by plugging in a

12VDC appliance. If not, clean accessory outlet and re-connect the 

Travel

Cooler/Warmer

.

• Fuse or circuit breaker in accessory outlet is open. Reset breaker or check fuse, and

replace fuse if necessary.

• Ignition is switched off - start engine or switch ignition to accessory position.

•  Fuse in unit's power cord is blown - see Fuse Replacement section for location of

fuse and instructions for checking and replacing fuse.

- Cooler/warmer is not cooling or heating properly (fan is not turning).

• Fan is defective. Call Vector® Customer Service department for

return/replacement instructions. This unit is not user-serviceable, it must be

returned to Vector Manufacturing for professional service or repair. Any attempt

to service by user will void warranty..

- Cooler/warmer is not cooling or heating, but fan is turning

• Cooling unit is defective. Call Vector® Customer Service department for

return/replacement instructions. This unit is not user-serviceable, it must be

returned to Vector Manufacturing for professional service or repair. Any attempt

to service by user will void warranty..

- Travel Cooler/Warmer takes longer than 30 minutes to reach design inside

temperature

• Low battery or supply voltage.

• Unit will attain design temperature more efficiently if items are pre-heated or pre-

chilled.

• Fan area is blocked - Move unit or object

SPECIFICATIONS:

Capacity  . . . . . . . . . . . . . 7 Liter / 1.85 Gallons (US)
Power Supply:  . . . . . . . . . 12-volt DC 
Power Cord:  . . . . . . . . . . 7’, with accessory  outlet-type plug and 10 Amp fuse
Amperage draw:  . . . . . . . 3.5 Ampers (approx. 42-watts)
Cooling Performance:  . . . Cools to average 40ºF below surrounding air (4.41ºC)
Warming Performance:  . . Warms to 120°F (54.41ºC) above surrounding air.
High Temperature Limit:  . . Automatic ON/OFF.
Cold/Heat Transfer:  . . . . . Temperature-efficient, aluminum-coated liner
Insulation:  . . . . . . . . . . . . CFC-free polyurethane liner
Heat Dissipation:  . . . . . . . Built-in fan with long-life, brushless motor
Warm/Cool System:  . . . . Non-wearing thermoelectric 

Summary of Contents for VEC246

Page 1: ...2003 VECTOR MANUFACTURING Ltd 4140 S W 28TH WAY FT LAUDERDALE FL 33312 AB060303...

Page 2: ...S WARNINGS INSTRUCTIONS AND PRODUCT LABELS FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 SW 28TH WAY FT LAUDERDALE FL 33312 TEL 954 584 4446 FAX 954 584 5556 TOLL FREE 866 5...

Page 3: ...Home or motel use with Vector s VEC002 AC DC Converter At the beach on picnics at the campground use with battery power For short term use When you have to leave the vehicle in the parking lot at the...

Page 4: ...s and feeding bottles FEATURES Compact lightweight completely portable use with vehicle or boat s 12 volt DC accessory outlet appropriate 12 volt DC power supply or AC DC Power Converter Non wearing t...

Page 5: ...es F This unit is intended for portable use only it is not designed to be built in or recessed this would interfere with the unit s air dissipation system and could cause a fire or other safety hazard...

Page 6: ...icle s accessory outlet and from the cooler 1 1 Store cord in the Cord Storage Hatch in the lid 12 Clean unit as described in the Care Maintenance section of this manual 13 Store in a cool dry area ou...

Page 7: ...itch is in the OFF position Insert one end of the unit s power cord into the power socket on the cooler Insert the other end into the 12 volt DC socket on the portable power supply Continue with steps...

Page 8: ...department for further instructions and possible return replacement This unit is not user serviceable it must be returned to Vector Manufacturing for professional service or repair Any attempt to ser...

Page 9: ...anty Cooler warmer is not cooling or heating but fan is turning Cooling unit is defective Call Vector Customer Service department for return replacement instructions This unit is not user serviceable...

Page 10: ...charges LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to u...

Reviews: