background image

13

12

7.1

SPOTLIGHT BULB REPLACEMENT

Tools needed – Phillips Screwdriver
1. Unscrew bottom center screw from clear plastic cover
2. Lift and remove clear plastic cover 
3. Unscrew the three screws holding the spotlight reflector (there are two screws

in the bottom and one on top).

4. Lift and remove black holding bracket from spotlight reflector
5. Spotlight reflector should be loosened
6. Gently lift the reflector and bulb assembly from the housing; note that the wires

are still attached to assembly

7. Unsnap the retaining wire from the reflector’s flange by pinching the two ends

together and lifting

8. Loosen the Phillips-head retaining screw (no need to completely remove ) to

loosen the bulb assembly from the reflector

9. Slightly turn and lift out the bulb from assembly ( reflector housing )
10. Disconnect the bulb’s assembly’s white wire from the red power wire by

separating the male spade terminal from the female terminal

11. Connect new bulb white wire to the red power wire
12. Insert the replacement bulb assembly into the reflector flange
13. Screw back in tightly the Phillips-head retaining screw from ( step 8 )
14. Snap back in the retaining wire from ( step 7 )
15. Place reflector and bulb assembly back into housing from ( step 6 )
16. Place black holding bracket from spotlight reflector ( step 4 )
17. Screw back in the three screws from ( step 3 )
18. Place plastic cover back into housing
19. Screw back in the center screw from ( step 1 )

7.2

FLUORESCENT BULB REPLACEMENT

Replacement bulb assemblies are available from an electrical supply house.  You may

also call Vector toll free (866) 584-5504 or visit our web site www.vectormfg.com.

Tools needed - Philips Screwdriver

1. Set the Spotlight lantern switch to OFF. 

2. Remove clear plastic cover as detailed in section 7.1

3. Grip ends of bulb and twist bulb (in any direction) until bulb pins align 

with notch on unit.

4. Remove bulb from unit by gently pulling straight out.

5. Insert replacement bulb into unit

6. Twist bulb to lock.

7. Return plastic cover as detailed in section 7.1

7.3

BATTERY REPLACEMENT

It is recommended that the unit be returned to Vector Customer Service for

battery replacement. Contact toll-free (866) 584-5504.

7.4

BATTERY DISPOSAL

The VEC270S contains a maintenance-free, non-spillable, sealed lead-acid

battery. This battery is fully recyclable and should be accepted at any location

that accepts common automotive starter batteries. Examples of places that

accept these batteries are: County or municipal recycling drop-off centers,

scrap metal dealers and retailers who sell automotive replacement lead acid

starter batteries. For more information on recycling this battery, call toll-free

(877) 288-7722.

8. FUSE REPLACEMENT

The VEC270S contains a 15 amp blade fuse located in the Air

Hose/Coupler/Fuse Compartment (Figure 1).

Tools needed - small needle nose pliers.

1. Open compartment cover (5).

2. Grasp blade fuse with needle-nose pliers and pull straight out.

3. Replace fuse with same size and type.

9. SPECIFICATIONS

Model . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VEC270S 
Battery Type(s)  . . . . . . . . 2 Sealed, high density, AGM, lead-acid, rechargeable,

maintenance-free, 6 volt DC, 4 Amp-hour

Spotlight  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . H3 15 Watt bulb 
Lantern  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Twin Tube Fluorescent 
Fuse  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Amp 
DC Charger/Adapter  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 volt DC/DC
AC Charger/Adapter  . . . . . . . . . . . . . 120 volt AC (500mA 12 volt DC Output)

DO NOT DISPOSE OF THE BATTERY IN FIRE AS THIS MAY

RESULT IN AN EXPLOSION. BEFORE DISPOSING OF THE

BATTERY, PROTECT EXPOSED TERMINALS WITH HEAVY-

DUTY ELECTRICAL TAPE TO PREVENT SHORTING

(SHORTING CAN RESULT IN INJURY OR FIRE!) DO NOT

EXPOSE BATTERY TO FIRE OR INTENSE HEAT AS IT MAY

EXPLODE.

Summary of Contents for VEC270S

Page 1: ...YOUR PURCHASE CALL TOLL FREE 866 584 5504 IN MOST CASES A SERVICE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE IF YOU HAVE A QUESTION OR COMMENT GIVE US A CALL YOUR FEEDBACK IS VITAL TO THE SUCCESS OF VECTOR S QUALITY IMPROVEMENT PROGRAM OWNER S MANUAL AND WARRANTY INFORMATION Air Compressor Inflator with Spotlight Lantern Combo KEY INFORMATION YOU SHOULD KNOW 260 PSI Compressor Multi us...

Page 2: ...ting articles can cause serious injury Always check pressure with the pressure gauge It is recommended to wear protective eyewear when inflating tires inflatable items 4 Always wear protective clothing i e no vinyl and eyewear when using INDICATES AN IMMINENTLY HAZARDOUS SITUATION WHICH IF NOT AVOIDED WILL RESULT IN DEATH OR SERIOUS INJURY INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH IF NOT A...

Page 3: ...ons this product contact with battery acid may cause blindness and or severe burns Be aware of first aid 5 Never recharge more than 5 hours maximum using 12 volt DC method more than 35 hours maximum using 120 volt AC method 6 To reduce risk of damage to plug and cord pull by plug and not the cord when disconnecting 7 Never operate charger if it has received a sharp blow been dropped or otherwise d...

Page 4: ...n the supplied power recharging cords or recommended appliance power recharging cords into the charging or power outlet on this unit Charging the battery while the vehicle s engine is not running is not recommended as it could drain the vehicle s battery If the unit is used too long after the red light comes on recharging could take up to 20 hours 11 10 Figure 1 Location Diagram 7 6 5 4 3 2 1 9 8 ...

Page 5: ...echarging with the 120 volt AC adapter Damage will occur to the unit accessory After the battery is charged the inflator is ready for use If the battery has not been charged please see section 3 1 120 Volt AC Charging before continuing 1 Remove valve stem cap and attach the universal adapter from the air inflator to the valve stem with the lever in the up position Be sure to press universal adapte...

Page 6: ...BE INFLATED 5 12 VOLT DC PORTABLE POWER SOURCE The unit s 12 volt DC power supply can power 12 volt DC items rated under 15 amps by simply inserting the item s plug into the 12 volt DC outlet 5 1 ESTIMATED 12 VOLT DC USAGE TIME 6 SPOTLIGHT LANTERN The spotlight lantern is controlled by an ON OFF switch on the side of the unit The spotlight provides the necessary light when working in low or no lig...

Page 7: ...Set the Spotlight lantern switch to OFF 2 Remove clear plastic cover as detailed in section 7 1 3 Grip ends of bulb and twist bulb in any direction until bulb pins align with notch on unit 4 Remove bulb from unit by gently pulling straight out 5 Insert replacement bulb into unit 6 Twist bulb to lock 7 Return plastic cover as detailed in section 7 1 7 3 BATTERY REPLACEMENT It is recommended that th...

Page 8: ...es LIMITATIONS This warranty does not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire...

Reviews: